Removal of PCBs
Step
3
Disconnect the
connectors [S46] [S48].
Pull out the relay
4
connector for the
reduction motor while
pinching the connector
from the back side of
the electrical box
cover.
Remove the 2 screws
5
and remove the control
PCB.
26
Procedure
Relay connector for
reduction motor
Points
[S46]: display PCB
[S48]: humidity sensor PCB
[S48]
[S46]
(R5705)
(R14164)
(R5708)
Removal Procedure
Si04-756