Si04-756

15.Removal of Streamer Unit

Procedure
Step
1. Remove the streamer unit.
Open the electrical box
1
cover and disconnect
the connector for the
streamer unit PCB
[S52].
Remove the screw of
the streamer unit.
Release the wire
2
harness for the
dehumidifying solenoid
valve coils from the
hook of the drip proof
cover.
Slide the streamer unit
3
to the right.
Remove the streamer
4
unit.
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Deodorizing filter
Streamer unit
for streamer
Electrode unit
Drip proof cover
Removal of Streamer Unit
Dehumidifying
solenoid valve coil
(R13976)
[S52]
(R5772)
Harness
(R5774)
Points
(R5773)
45