Error Signals; Maintenance/Customer Service - Siemens DG30037E Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 6
If warm water is not required for an extended period, set
the tank to frost protection mode with button 6
Only red LED 9 lights up.
The tank must be drained fully by our customer service
department or an authorised specialist in order to avoid
frost damage, if the appliance is disconnected from the
electrical supply.
The device should be disconnected from the mains supply
when working on the water supply.

Error signals

LEDs 9 and 2 flash
Overheating protection has been activated.
Call customer service.
LEDs 9 and 4 flash
The temperature sensor is defective.
Call customer service.
Rated capacity
Rated voltage
Rated output DGxxx37E
Rated output DGxxx37R
Rated output DGxxx37P
Rated current DGxxx37E
Rated current DGxxx37R
Rated current DGxxx37P
Fuse protection
Protection type/class
Rated over-pressure DGxxx37E
Rated over-pressure DGxxx37R
Rated over-pressure DGxxx37P
Cold and warm water connection
Corrosion prevention
Warm water temperature range
Frost protection
Insulation thickness
Stand-by power consumption at
65 °C
Mixed water quantities at 40 °C
(15 °C/65 °C)
Heating time (inlet 12 °C -> 60 °C)
DGxxx37E
DGxxx37R/DGxxx37P
Weight [filled]
Dimensions (H x D)
GB
Cleaning
Clean externally with a mild cleaning agent. Do not use
aggressive or abrasive detergents!

Maintenance/Customer Service

Repairs and other maintenance work may only be
carried out by one of our authorized customer service
representatives in order to avoid potential sources of
danger.
When you contact customer service, please quote the E
and FD numbers on your appliance (Fig. A).
The first inspection must be carried out no later than 2
years subsequent to initial startup of the appliance. This
involves inspection of the protection anode which may
need to be replaced, and the appliance may need to be
cleaned and descaled. The customer service will suggest
the next inspection date for a service.
The power supply and the water supply must be shut off
before all work on the appliance.
T e c h n i c a l d a t a
[l]
30
[V]
[W]
[A]
[A]
[Mpa]
[°C]
[°C]
[mm]
30
[kWh/d]
0,65
[l]
54
[min]
68
51
[kg]
49
[cm]
58 x 39
50
80
220–240 (~ 50 Hz)
1500
2000
2000
6,5
8,7
8,7
10
IP24D
0,9
0,9
0,6
G 1/2"
Magnesium protection anode
approx. 35-75
approx. 10
35
0,85
1,05
90
144
114
182
85
137
70
107
65 x 45
90 x 45
100
1,25
180
228
171
131
109 x 45
9

Advertisement

Table of Contents