Catalog Numbering System For 955Qd - Ametek Gemco Brik 955QD Series Installation, Programming And Maintenance Manual

With qudrature output, linear displacement transducer
Table of Contents

Advertisement

3.8: Catalog Numbering System for 955QD

955QD
0120
The Series 955QD
The Brik
with Quadrature Output
Stroke in Inches
Insert stroke in inches to 0.1 inch. Enter as a four-
place number. Example: 12.0 in stroke entered as
0120. To convert a metric stroke in millimeters, multi-
ply millimeter value by 0.03937 to arrive at inch value.
Connector Style
H = HRS Environmental Connector
Consult factory for others
Output Resolution
Cycles per inch, maximum internal resolution is 0.001 inches
1000 standard (available range is 0001 through 9999)
Input Type
E = Sinking (typically used with sourcing output type)
C = Sourcing (typically used with sinking output type)
T = TTL Level
Quadrature Cycle Output Frequency Range
F1 = 10 KHz F2 = 25 KHz F3 = 50 KHz F4 = 75 KHz
F5 = 100 KHz F6 = 150 KHz F7 = 250 KHz F8 = 500 KHz F9 = 1.00 MHz
Consult our Technical Support for other output frequencies.
Output Mode
M1 = X1 Quadrature, Consult factory for other output modes
Zero Offset Storage
V = Volatile (nonretentive) N= Nonvolatile (retentive, 100,000 storage cycles maximum)
Output Drivers
D = Differential RS422 line driver, TTL compatible
L = Differential line driver 10 - 30VDC, V out = V in (LDT Power) -1 volt
Options
X = None
NOTE: Contact our Technical Support Department for custom congurations.
H
1000
Installation, Programming and Maintenance Manual
Chapter 3: 955QD Overview
E
F7
M1
N
D
X