SpeciCations For 955Qd - Ametek Gemco Brik 955QD Series Installation, Programming And Maintenance Manual

With qudrature output, linear displacement transducer
Table of Contents

Advertisement

Chapter 3: 955QD Overview
3.9: Specications for 955QD
General Specications:
Null Zone
Dead Zone
Extrusion Assembly
Connector
Sensor Length
Agency Approval
Shock and Vibration
Random Vibration
Shock
Electromagnetic Compatibility
IEC 801-2, Level 3 (Electrostatic discharge requirements)
IEC 801-4, Level 3 (Electrical fast transient/burst requirements)
Electrical Specications
Input Voltage
Unipolar
Current Draw
Nonlinearity
Repeatability
Operating Temperature
Storage Temperature
Drivers
Option D
Option L
17
3.00"
1.50"
Anodized Aluminum with gasket seals, IP 67
HRS-Style Standard (quick connect/disconnect) Connector
Up to 14'
CE
MIL-STD 810E, 10Grms random, 20Hz - 2K Hz
Tested to 40G
10 to 30 VDC
3 watts maximum, (1 watt, typical)
Less than 0.05%
+/- 0.001% of full stroke or +/- 0.001" (0.0254 mm), whichever is greater
-20° to 70° C
-40° to 85° C
1. Quadrature A:
2. Quadrature B:
3. Zero (index) position
maximum 5 volts, minimum 2 volts into a 50 ohm load
1. Quadrature A:
2. Quadrature B:
3. Zero (index) position
Maximum 30 VDC, min 10 VDC, driver 0L7272
V out = V in (LDT Power) - 1 volt
Installation, Programming and Maintenance Manual
RS-422 differential
RS-422 differential
RS-422 differential
differential line driver
differential line driver
differential line driver

Advertisement

Table of Contents
loading