to power the LDT. When powering more than one
VMAX on a single power supply, remember that each
unit requires approximately one watt of
power. The amount of current draw will vary based on
the input voltage used. To calculate the current draw
for a particular LDT, divide the LDT wattage by the
input voltage. For example, 1 watt divided by 24 VDC
equals 41.6mA.
If the LDT is not operating properly, the LDT's cable
may have an open or short, or the power supply is not
supplying sufficient power. To verify this:
1. Turn the power supply off.
2. Remove the mating connector from the LDT.
3. Turn the power supply on.
4. Using a digital voltmeter, check across Power Supply
Common and customer supplied power (+VDC) on
the mating end of the cable for a level between 7 and
30 VDC.

Appendix B: Part Numbering

953A
V0
0120
Output
V0
0 to 10 VDC
Blank Inches
V1
10 to 0 VDC
M
-10 to 10 VDC
V2
V3
10 to -10 VDC
V4
0 to 5 VDC
V5
5 to 0 VDC
Insert stroke length to 0.1 inch. Enter as a four-
V6
-5 to 5 VDC
place number. Example: A 12.0" stroke enters as
V7
5 to -5 VDC
0120.
OR
C4
4 to 20mA
Insert stroke in millimeters to 1mm. Enter as a
20 to 4mA
C2
four-place number. Example: 305mm stroke entered
as 0305M. Metric length includes metric mounting,
M18x1.5. Unless specified otherwise.
NOTE 1: On unsupported stroke
lengths greater
than 4 feet, rod support bracket(s)
and a special magnet
should be used.
NOTE 2: Specify magnet as sepa-
rate line item.
Standard magnet is SD0400800.
S Connector Style
5 Pin Micro, 12mm Euro
1080 N. Crooks Road • Clawson, MI 48017 • 800.635.0289 • Phone 248.435.0700 • Fax 248.435.8120 • www.ametekapt.com
VP
X
Null Zone
Units
X
Standard 2 inches.
Insert non-standard Null
Metric Base
N_
Zone (1.5" Minimum).
and Threads
Stroke Length
X
D_
M Connector Style
6 Pin DIN, Fits MTS D60
8 Pin DIN, Fits Balluff S32
Appendix B: Part Numbering
NOTE: LDT's with integral cable assemblies
should be checked for proper voltage at the power
supply terminals. This cable assembly cannot be
removed from the LDTIf the reading is between 7
and 30 VDC, turn power supply off and go to step
7. If the reading is below 7 VDC, either the power
supply is not providing enough power or the LDT's
cable possibly has a short or open. A reading of
no voltage or minimal voltage (less than 5 volts)
may be due to a short or open in the cable. If the
reading is not between 7 and 30 VDC, go to step
5. If the reading is above 30 VDC, adjust power
supply or replace.
5. Turn the power supply off.
6. Check the continuity of the individual wires of
the cable between the power supply and the
LDT. Check for continuity from one end of the
cable to the other. Also, verify that no shorts
exist between pins.
7. Reconnect the mating connector to the LDT.
X
S
Connector Option
S
Standard 5 Pin, 12mm Euro
Integral Cable Assembly.
Insert length in feet. Example:
C_
C6 = 6 foot cable.
M
6 Pin DIN, MTS Style D60
B
8 Pin DIN, Balluff S32
Environmental 10 Pin MS
Connector compatible w/951 &
952 LDTs
E
w/connector option "E".
o
High Temp., Integral cable
assembly 200 C Teflon Cable.
H_
Insert length in feet. Example: H6=
6 foot High Temp Teflon Cable.
Dead Band
X
Standard 2.5 inches.
Insert non-standard Dead
S
Band (2.25" Minimum).
B Connector Style
C Connector Style
Integral Cable Assembly
X
Optional Housing Style
Mounting Threads
Raised face hex base
(Standard) - Threads will
Blank
be the same as "Units
of Measure" unless
specified otherwise.
US Threads with raised
R
face hex base
US Threads with flat
F
face hex base
Metric Threads with
M
raised face hex base
Metric Threads with flat
N
face hex base
Sensor cartridge only
C
No hex base
Options
None
Stainless Steel cover and
connector. Only available
with connector options S,
C and H.
E Connector Style
10 Pin MS Connector,
Fits Gemco 951 & 952 Wiring
AUTOMATION & PROCESS TECHNOLOGIES
®
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gemco 953a vmax