Usb Interfaces Xusb1 To Xusb6 - Bosch Rexroth IndraControl VPB 40.3 Operating Instructions Manual

Control cabinet pc
Table of Contents

Advertisement

Bosch Rexroth AG
Interfaces
The following conductor cross-sections are permitted for the spring terminal at
X10:
Conductor
Conductor cross-section inflexible, max.
Conductor cross-section inflexible, recommended
Conductor cross-section flexible, max.
Conductor cross-section flexible, recommended
Conductor cross-section flexible with core end sleeves without plastic sleeve,
max.
Conductor cross-section flexible with core end sleeves without plastic sleeve, rec-
ommended
Conductor cross-section flexible with core end sleeves with plastic sleeve, max.
Conductor cross-section flexible with core end sleeves with plastic sleeve, recom-
mended
Conductor cross-section AWG/kcmil, max.
Conductor cross-section AWG/kcmil, recommended

9.4 USB interfaces XUSB1 to XUSB6

The devices are provided with six USB interfaces on the connector panel
(XUSB1/2 XUSB3/4 and XUSB5/6).
Fig. 9-2: Current carrying capacity of the six USB connections
①: The USB ports are monitored in pairs. If, e. g. XUSB1 switches
off, as the power consumption has been exceeded (> 500 mA),
XUSB2 switches off as well.
16/57
Maximum
power consumption
XUSB1, XUSB2
each port 500 mA
XUSB3, XUSB4
each port 500 mA
XUSB5, XUSB6
each port 500 mA
Control Cabinet PC
Cross-section
10 mm
2.5 mm
6 mm
2.5 mm
6 mm
2.5 mm
4 mm
2.5 mm
8
13
1
Maximum total power
consumption without
plug-in cards: 3 A
Maximum total power
consumption with
plug-in cards: 1 A
DOK-SUPPL*-VPB*40.3***-IT05-EN-P
2
2
2
2
2
2
2
2