User Manual – Rev J
3.6.1
AC Input Connector – INPUT (TB3)
See section 3.4 for details on connecting AC input power. Labeled INPUT on CS models.
INPUT.
Designator
CS Series
1
ØA
2
ØB
3
ØC
4
GND
3.6.2
SMA Connectors
SMA connectors. Functions are called out on rear panel decal. Table 3-4 shows connections
from left to right when standing at the rear of the CS cabinet. SMA connectors are small high
frequency capable coax connectors that can be screwed down securely to prevent signal loss.
Adaptor for SMA to BNC conversion are readily available.
To connect these signals using more conventional BNC cables, SMA Male to BNC Female
adapters may be used. These are available from
SMA
FLT
INH
FSTB
TRIG
RPV(N/A)
3.6.3
BNC Connectors (-LKM / -LKS options)
BNC connectors. Functions are called out on rear panel decal. Table 3-5 shows connections for
the optional -LKM and -LKS clock and lock mode. Refer to section 3.9 for more details.
BNC
CLOCK
LOCK
California Instruments
Direction
Input
Input
Input

Table 3-3: AC Input Terminal Block Connection Description

Description
Discrete Fault Indicator output. Isolated Open Collector. Can be used to signal external
devices when a fault condition is detected.
Remote Inhibit. (TTL input)
Function Strobe / Trigger Output (TTL output)
Trigger Input (TTL input)
Remote programming voltage. DC voltage input 0 to +10 VDC for 0 to full-scale output
voltage programming.(RPV option)
Table 3-4: SMA Connectors – CS Series
CS Series
Description
Ref.
J1
Clock Option (TTL output on Master / TTL input on Auxiliary) N/A
J2
Lock Option (TTL output on Master / TTL input on Auxiliary) N/A
Connection
Description
AC Line
AC Line
AC Line
Chassis Ground
www.pasternack.com
PE9074 Adaptor.
CS Series