10
Technical Data
10.1
Main data
Name
Description
Order no.
Analog inputs
Number
Design
Resolution
Filter
Input signal range
Input impedance
Sampling rate
Frequency range
Accuracy
±1 V; ±2.5 V; ±5 V; ±10 V; ±24 V
Electrical isolation
Channel-housing/power supply
Connector type
ibaNet interface
Number
Design
ibaNet protocol
Data transmission rate
Sampling rate
Connector type
Power supply
Power supply
Power consumption max
22
Manual
ibaPADU-4-AI-U
Input module with 4 analog voltage inputs
10.121000
4
Galvanically isolated, single ended
16 Bit
permanent
R/C low-pass, 1
in addition
Analog anti-aliasing filter (Butterworth) 4
Digital anti-aliasing filter, 8
of the adjusted sampling rate
±250 mV; ±500 mV; ±1 V; ±2.5 V; ±5 V; ±10 V; ±24 V
100 kΩ
Synchronous with ibaNet sampling rate
0 Hz to 50 kHz
± 250 mV; ±500 mV
< 0.5 % of total measuring range
< 0.1 % of total measuring range
Channel-channel
AC 1.5 kV
AC 1.5 kV
1 x12-pin multi-pin connector
screw-type terminal (0.14 mm² bis 1.5 mm²) screw
connection, included in delivery
1
Fiber optic cable
32Mbit Flex (bidirectional)
Can be used simultaneously for data, settings and
service (e. g. updates)
32 Mbit/s
Up to 100 kHz, freely adjustable
2 ST connectors (62.5 µm / 125 µm) for RX and TX,
cable length up to 2000 m without repeater
24 V DC (±10%)
10 W
Issue 1.1
ibaPADU-4-AI-U
order, 72 kHz
st
th
order, cutoff frequency 1/3
th
order, 50 kHz