 Min
You can define a lower limit for the measuring range. The analog normalized value
of -5 V is assigned to a physical value, e. g. -100 V.
 Max
Here, you can define an upper limit for the measuring range. The analog normal-
ized value of +5 V is assigned to a physical value, e. g. +100 V.
 Filter
You can activate the antialiasing filters (analog + digital).
 Active
The signal will be measured when active.
 Actual
Displays the actual value of the signal (only available when the measurement is al-
ready running with the specified configuration).
 Further columns can be shown or hidden by using the context menu (right mouse
click in the table header).
9.4
PADU-4-AI-U – "Diagnostics" tab
Figure 9: ibaPADU-4-AI-U –"Diagnostics" tab
Here, you find information about the hardware version, firmware version, FPGA version
and the serial number of your device.
 Write firmware
Using this button you can install a firmware update. Select the update file
"padu4_v[xx.yy.zzz].iba " in the browser and start the update with <OK>.
20
Manual
Issue 1.1
ibaPADU-4-AI-U