Output Connection - HANYOUNG NUX GE Series Instruction Manual

Table of Contents

Advertisement

To prevent chattering during the use of Contact Input Counter, setup the
coefficient speed at 1 or 30 cps in Function Setup Mode.
Timer Mode Setup Method
Function Setup Mode (Timer / Twin timer)
Setup Item
1 Stage setup type
Device
Change
Scale
Time
range
In TIM(TIMER) setup
Operation
Mode
In TTIM(TWIN TIMER) setup
In Total ( Di s pl a y onl y )product
Output
* One short or
time
self-maintenance for OUT2(OUT)
BATCH
Output
Input
time
Memory
for power
failure
Input
NPN Input
logic
PNP Input
Key
Lock
Key lock setup in operation
condition (4stages)
Total(Indicator) type of product does not have setup mode for output time and Batch
One stage output mode does not have twin timer function
Input Logic Setup Status can be
verified in Function Setup Mode.
Internal Impedance is 4.7 , and
switches over to Pull Up or Pull
Down from NPN/PNP Selection.
(Refer to Input Connection)
BATCH Output
Initial value
Contents
Timer
2 Stage setup type
Twin Timer
10 (Decimal) / 60 (Sexagesimal)system
0.01sec ~ 999999(9999)h
UP/DOWN selectable
Twin timer
is not available with
1 Stage output model.
Refer to output operation mode char
* No display for Total and TWIN TIMER
mode
Set Batch output port
:Relay
: Transistor)
Minimum input time selection 1
/20
(INHIBIT), (START), RESET
Current time and Batch count
value are saved when power failure
Remove a data when power failure
Convertible by dip switch It is not available
to change setup in power input menu.
Key Lock
No use for all keys (
,
,
No use
keys
Indicated Time Range
Range Selection
UP
s : second m : minute.

Output Connection

Timer Operation Mode
TIM(TIMER)Setup
Power RUN / ON delay
Signal START / ON delay
Signal START / ON delay
Signal RUN / ON delay
Signal RUN / OFF delay
Interval / Signal RUN
Interval / Signal START
Flicker / Signal START
Flicker (Counter
Flicker (Counter
Flicker (Counter
Signal Addition
CP1/INHIBIT function stops the time.
[S.---] is activated when CP2 (START) is 'ON'
[S ---] is activated when CP2 is maintained 'ON', and resets when 'OFF'.
[P ---] activates with 'POWER ON'
Setup
power during 'POWER OFF' (Indicates the Memorized Value when electric
power is inputted again.)
Timer[TIM]Output Operation
1 Stage Setup Type Output is OUT.
INHIBIT (CP1) temporarily stops the time.
Power RUN / ON delay
key exception)
,
No use keys
Runs when 'POWER ON'
When Reset signal is authorized, process value initializes and runs.
4 digits Time Range
Sexagecimal
Decimal
DOWN
System
System
99.99 s
59.99 s
999.9 s
9 m 59.9 s
59 m 59 s
9999 s
99 h 59 m
9999 m
99 d 23 h
9999 h
h : hour
d: day
Example of Non-Contact Output
Connect surge observer (diode,varistor)
on the both ends of the load when using
inductive load (relay etc.),and must use
with GND since the internal circuit and
non-contact output are isolated from one
another.
Calculate power load and load to prevent
the non-contact output from exceeding the
maximum of 30 V 100
Example of Contact Output
Avoid the flow of excessive current since it
is 250 V a.c NO 3 A (loadresistance) NC 2 A
(load resistance), and theconnection must
correspond to standard connection method.
TTIM(TWIN TIMER)Setup
Power RUN
ON delay
Power RUN
OFF delay
Signal START
ON delay
Signal START
OFF delay
Mode)
Power ON RUN
Mode)
OFF time
Mode)
as
in order to compensate for interruption of electric
6 digits Time Range
Sexagecimal
Decimal
System
System
59 m 59.99 s
9999.99 s
9 h 59 m 59.9 s
99999.9 s
99 h 59 m 59 s
999999 s
9999 h 59 m
999999 m
9999 d 23 h
999999 h
For TOTAL Model
Power RUN
Signal RUN