HANYOUNG NUX GE Series Instruction Manual page 4

Table of Contents

Advertisement

Counter Mode Setup Method
Counter Function Setup Mode
Setup Items
1 Stage setup type
Setup list
Input
Mode
Output Mode
Output Time
Output Time
BATCH
OUTPUT
Counting speed
PRESCALE
PRESCALE
Decimal Ponit
Setup
Setup decimal
point in display
RESET TIME
Memory for
power failure
Input Logic
Key Lock
Key Lock
Pressing
key will return to operation mode without saving. Return to operation mode if there is no key
input more than 60 seconds. With function setup mode, it ignores external signal input and maintains
output in OFF state.
TOTAL product does not display setup lists such as output mode, OUT2 output time, OUT1
output time, BATCH output and etc
Level 1 setup product does not display OUT1 output time setup list.
Selecting
for BATCH output setup will restrict setup function and display function.
Convert Operation Mode to Function
Mode -> Press MD key for 2 seconds
Contents
1 Stage setup counter
2 Stage setup counter
2 Stage setup type
CP1,CP2 Dual inputs UP mode operatio
CP1,CP2 Dual inputs down mode operation
Refer to Input operation Mode (Counter)
Refer to Output operation Mode (Counter)
(D setup is self-maintenance output)
One short delay time
One short time setup
No display for level 1 product
Set Batch output port
Relay
Transistor
or
is set when contact is used with maxmum input speed
Initial Value
set up to 5 decimal points and possible to move up
to 4 decimal points
Setup decimal point in display and possible to
move up to the third decimal point
Minimum signal width of external reset signal input
Coefficient value is saved when POWER become OFF
Coefficient value is initialized when POWER become OFF
Vary depends on internal switch conversion
Cancel Key Lock
Do not use any keys (except
Do not use
,
Do not use front side
Counter input operation mode
'A' needs value greater than min signal width, B need value greater than half of
min signal width.
Initial value
When using encoder (incremental method). Please use
Noice) The input Login of above list is PNP.
Counter Output operation of Exclusive Indication (GE-T)
RESET
Set value is first to decrease within Down Mode
key)
6 digits: if -99999(-999), it flashes and does not get counted
Within UP MODE, it increases to the maximum display value, initializes to
,
,
key
0 and increases again
key
UP
DOWN
Flashing
UP/DOWN A,B,C
Flashing

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ge4-p1Ge4-p2Ge6-p1Ge6-p2Ge3-p1Ge3-p2 ... Show all

Table of Contents