Coefficient Input 1(CP1) / Inhibit Input (INHIBIT) Terminal
With using counter, it is used as coefficient input or coefficient inhibit
Process time become HOLD when timer function is selected
Coefficient Input 2(CP2) / Start (START) Terminal
With using counter, it is used as coefficient input or coefficient inhibit
With using timer, it can be used as SIGNAL ON START, SIGNAL ONE
START. (Refer to output mode operation)
(SIGNAL ON START: Timer operates only with the continuous input.)
(SIGNAL ONE START: Timer operates only with the supply of Input 1 Pulse.)
BAT. RESET
This is used as BATCH, RESET during the use of counter / timer.
RESET
This initializes the coefficient value and current time during the use of
counter / timer.
OUT, OUT2 : This is used as the counter / timer comparative output.
BAT.O : Batch Counter Output (1 Stage Setup Type)
OUT1(BAT.O): Select between 2 Stage Setup Output and Batch Counter
Output (2 Stage Setup Type)

Name of Each Section

GE3
GE6
GE4
GE7
Coefficient display (RED FND)
Display coefficient value (counter), time process value (timer), batch coefficient
value and setup list.
Setup display (GREEN FND)
Display setup value (counter), setup time (timer), batch setup value, instant
output setup (batch setup is 0 in Timer) and setup contents
SET1, SET2 (SET), BAT
Indicates the status of coefficient section and setup section
(BAT lamp corresponds to batch status.)
TIM (Timer)
This flashes when the timer progresses and remains lighted when the device
stops from inhibit input or reset.
(It is indicated in Change Mode of the device during TIM/TTWIN setup.)
CNT (Counter)
This is indicated during 1CNT/2CNT setup in Change Mode of the device.
OUT1, OUT2(OUT), BAT.O (Output Action Indication)
BAT.O lights up when the batch setup value is set. (OUT1 Output)
BAT.O lights up and outputs when the device operates with the instant output
where the batch setup value is 0 (timer).
CP1, CP2, RST: Verification of Input Status. (Exclusively for TOTAL)
LOCK:Key Lock (KEY LOCK) Action IndicationThis lights up during Lock Setup.
This key is for function setup Mode Entry and Mode change. It can also be
used for ending after saving when changing the setup value
Setup value change Entry and Location shift
UP Key
RESET KEY
When SET, BAT lamp light, RESET key will not operate.
Batch and operation mode 1 stage and 2 stage conversion key. When BAT
lamp light, it is batch mode and keep operate.
Push both of keys together, It operate same as
DOWN Key
TOTAL Model does not have Setup Indication Section, SET1, SET2 and BAT
Lamp. OUT1, OUT2, BAT.O change their use as CP1, CP2, RST Input Status
Check Lamp. 1 Stage Setup Model does not have SET1 and OUT1 Lamp, and
SET2 is displayed as SET and OUT2 is displayed as OUT.
Maximum Coefficient Speed
Maximum coefficient speed is maximum response speed when entering in the
duty ratio (ON. OFF ratio) of coefficient input signal as one to one ratio (1:1)
As for the input signal below the maximum coefficient speed, if either ON or
OFF time is unilaterally less than the standard value of minimum signal width
then it may not be counted
Minimum Input Time
Coefficient Speed Selection
Minimum Input Signal
1 cps
250
30 cps
11
1 K cps
0.3
10 K cps
0.05
key.
Minimum Signal Time refers
to 'ON' Time.