Input Connection - HANYOUNG NUX GE Series Instruction Manual

Table of Contents

Advertisement

Counter Output Action Mode
As for 1 Stage Counter (OUT), it is the same as
2ND Output (OUT2) Action.

Input Connection

NPN (Non-Voltage Input)
Non-Contact Sensor
Connection Method
PNP (Voltage Input)
Non-Contact Sensor
Connection Method
One Shot Time Delay
Contact Sensor
Connection Method
Contact Sensor
Connection Method
One Shot Output of OUT1 Output
Self-Maintenance Output Self-Maintenance Output
Post Count Up Action
Coefficient value indication is maintained and setting
up HOLD (0) leads to self-maintenance output. Also,
setting up time leads to OUT2 output after one shot
delay setup. OUT1 and OUT2 become OFF when
reset and return to Start.
Coefficient value indication is continuously processed
and setting up HOLD (0) leads to self-maintenance
output. Also, setting up time leads to OUT2 output
after one shot delay setup. OUT1 and OUT2 become
OFF when reset and return to Start
Coefficient value indication is continuously processed
during START state and OUT2 yields One Shot
Output. Self-maintenance output of OUT1 is turned
off when OUT2 is turned OFF
Coefficient value indication is maintained during One
Shot Time, and then resets. (Repetitive Action)
Coefficient value indication is continuously processed.
OUT2 yields one shot output. Self-maintenance
output of OUT1 is turned off after one shot time of
out2
When coefficient value returns to initial state, then
coefficient value indication is maintained for one shot
time. After processing one shot time, it displays
processed coefficient value.
Coefficient value increases and OUT2 yields One
Shot Output. The device is reset after the One Shot
Output.
(Repetitive Action)
Coefficient value is maintained and OUT2 yields one
shot output. OUT1 and OUT2 are independent from
each other.
If #OUT1 is same as setup value of SET1, it leads to
one shot output or self-maintenance output. (In case
of Level 1 setup type, OUT1 and OUT2 are same
each other)
# Reset refers to OUT1 and OUT2 become OFF and
coefficient value being initialized.
Input Logic Selection
Operate the conversion switch after confirming NPN/PNP indication which is
displayed on the top
Input Method
Voltage Input
H
L
Input Method
Voltage Input
H
L
For receiving Open Collector Input, Input Logic (PNP/NPN) Conversion
Switch is embedded internally to Pull up / Pull down the resistance of 4.7
(NPN Setup during shipment)
Select One Shot
Output between
0.01ms~99.99ms
One Shot Output of OUT2 Output
PNP Setup
PNP O.C
NPN Setup
PNP O.C