Parts And Exploded View - Silver King SK-2 Operation Manual

Cream dispenser
Table of Contents

Advertisement

Cream Dispenser
Model SK-2
PROBLEM
Compressor will not run
Compressor runs but no refrigeration
Compressor short cycles
Compressor runs too much or constantly
SK-2 Cream Dispenser
Troubleshooting Steps
Master Display Messages
PROBABLE CAUSE
No Voltage at wall receptacle
Service cord pulled out of wall receptacle
Low voltage causing compressor to cycle on
overload
Power switch is in "Off" position
Inoperative Control
Compressor stuck
Compressor windings open
Compressor overload stuck open
Relay lead loose
Relay loose or inoperative
Power cord disconnected from dispenser
Faulty cabinet wiring
System out of refrigerant
Compressor not pumping
Restricted filter drier
Restricted capillary tube
Moisture in system
Erratic Control Thermostat
Low Voltage
Compressor draws excessive wattage
Faulty relay
Temperature too low
Erratic Control
Abnormally high room temperature
Door or lid gaskets not sealing
System undercharged due to leaks
System undercharged from factory
System overcharged
System not clean
Restricted filter drier
Restricted capillary tube
11
SOLUTION
Check circuit breaker or fuse
Call for service (888-375-2938).
Contact power company and confirm that
voltage fluctuation does not exceed 10%
plus or minus from the nominal rating.
Turn switch on
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Contact power company and confirm that
voltage fluctuation does not exceed 10%
plus or minus from the nominal rating.
Call for service (888-375-2938).
Call for service (888-375-2938).
Adjust temperature control
Call service technician
Reduce room temperature or relocate dis-
penser
Adjust or Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).
Call for service (888-375-2938).

Hide quick links:

Advertisement

Table of Contents
loading