6

Commissioning

6.1 Test Run

Ideally, test the fan for 10 minutes to see if there is any unusual noise, vibration from the
device or from the safety steel ropes.
Also make sure that the fan runs safely with a sufficient safety distance to all possible
obstacles.
Commissioning;
1. Make sure that the fan can run free of
obstacles.
2. Check the direction of rotation of the blades,
regular operation is counter-clockwise.
3. Make sure that the input voltage is correct and
meets the requirements.
4. Set the speed controller to the minimum
position.
5. Switch on the fan and turn the switch from STOP
to RUN.
6. After the fan has started, set the speed control
knob to the desired speed.

6.2 Warnings

A change in shape or the bending of rotor blades is strictly prohibited.
Please do not carry out any work or repairs while the device is switched on in order to
avoid an electric shock.
Please do not change the original technical structure of the fan.
Please do not open the switch box / controller box during operation to avoid an
electric shock.
Do not operate devices with malfunctions as this can lead to serious injuries.
Structural or parameter changes to the electrical control box are strictly prohibited, as
this can lead to equipment damage, injuries or death due to improper use.
After disconnecting the power supply, there may still be a residual voltage in the
controller box. Wait 2 minutes until the contacts are de-energised. Switching off the
display is not an indication that there is no voltage.
The installation and laying of the electrical cabling must be carried out by a qualified
specialist.
Please use the device components enclosed and specified by MonsterFans.
Do not interrupt the power supply while the fan is running. Otherwise the fan will be
damaged. The power supply may only be switched off, after the rotating blades have
stopped completely.

6.3 Troubleshooting

Common causes of incorrect operation:
The supply voltage is incorrectly selected or switched off.
If the fan does not work, please check first if the speed controller is at MIN and check
also the Run/Stopp button.
Unauthorised personnel must not open the Controller Box. Our local service partner will
send you a trained specialist for repairs or adjustments.
If you notice, that the fan or Controller Box is damaged or has unusual noises, stop using
it with immediate effect. Switch off the power supply and contact your service partner.
A damage of the device caused by improper use is not covered by the warranty.
www.monsterfans.com
Caution:
1. It is prohibited to interrupt the
power supply during fan
operation.
2. The fan is not designed for reverse
operation.
3. The direction of rotation can only
be changed by phase rotation on
the frequency converter.
info@monsterfans.com