1
Use Instruction
Schwank GmbH - Bremerhavener Str. 43 - D 50735 Cologne
Tel: +49 (0)221-7176-0
www.monsterfans.com
Language:
Englisch
Date:
10. September 2020
Revision:
V 1.1
Fax: +49 (0)221-7176-288
info@monsterfans.com

Advertisement

Table of Contents
loading

Summary of Contents for Schwank MonsterFans MF-C12

  • Page 1 Use Instruction Schwank GmbH - Bremerhavener Str. 43 - D 50735 Cologne Tel: +49 (0)221-7176-0 Fax: +49 (0)221-7176-288 www.monsterfans.com info@monsterfans.com Language: Englisch Date: 10. September 2020 Revision: V 1.1...
  • Page 2: Table Of Contents

    Table of content: Introduction ......................3 Specifications ......................3 Safety Instructions..................... 3 Placement & Distances ..................4 Checklist ........................ 5 Parts Overview MonsterFans ................... 6 Bill of Materials ...................... 6 Required Tools ....................... 8 Installation & Mounting .................... 8 Safety Clearances ....................8 Safety Distances to Ventilation Systems .............
  • Page 3: Introduction

    Introduction Congratulations on your MonsterFans‘ purchase. The High Volume Low Speed fans (HVLS) of the MonsterFans series are energy-saving units with high comfort and diameters from 3.6 m (12ft.) to 7.3 m (24 ft.). They move big amounts of air at low rotational speed. The blades are streamlined and ideally engineered according to the principles of aerodynamics.
  • Page 4: Placement & Distances

    Follow these installation instructions during installation. Please do not make any changes to components. Install the device completely before putting the device into operation. To avoid the risk of electric shock, note the following: a) Use this device only as intended by the manufacturer. If you have any questions, please contact the manufacturer or your local service partner.
  • Page 5: Checklist

    2.2 Checklist ☐ Do you have the right mounting set for your mounting position? The standard mounting set supplied with this fan for I-beam, allows the fan to be hung on steel beams. Do not mount the fan on a purlin or a framework. If you are unsure, please contact customer service.
  • Page 6: Parts Overview Monsterfans

    Parts Overview MonsterFans 1. Steel structure 2. Safety rope ring 3. Steel structure fastening 4. Extension tube 5. Motor housing 6. Winglets of fan blades 7. Fan blades 8. Turnbuckle & clamps 9. Safety steel rope 10. I-type safety adapting piece 3.1 Bill of Materials www.monsterfans.com info@monsterfans.com...
  • Page 7 Bill of materials - MonsterFans 1. Motor Housing 2. Top-Plate 3. Spacer 4. Beam clip 5. Turnbuckle 4x 6. I-type fan 7. Fastener M5 x 12 mm 8. Bottom plate & 1x replacement blade retainer 5x 9. Safety steel rope 10.
  • Page 8: Required Tools

    3.2 Required Tools Spanner Set Socket Wrench Screwdriver Spirit Level Electr. Cable Cross & Slot shielded 4 x 2,5 mm² Cable Shears Wire Stripper Multimeter Distance Meter Threadlocker Glue Please also note the necessary safety precautions for the use of a scissor lift and the general safety precautions.
  • Page 9: Required Installation Environment

    If the air supply outlet of a ventilation system is below the blades, a minimum distance of 1 times the fan diameter from the blade tip is sufficient. If the air supply outlet of a ventilation system is located above the blades, a minimum distance of 2 times the fan diameter from the blade tip is necessary.
  • Page 10: Mounting Sets

    4.4 Mounting Sets The fans are usually connected to an I-beam Accordingly this element as standard is included in every packaging unit. Standard Mounting Set (for I-Beam) Article no 19580220 Weight: 14 kg Optional mounting set for concrete structure Mounting Set concrete structure Article no.
  • Page 11: Extension Elements

    4.5 Extension Elements The MonsterFans fans are delivered ex works with a hanging element of standard 1.5m. Optionally, we offer another 1 m and 2 m extension element and a connection piece to connect two extension elements. The max. length of these extension elements must not exceed 3 m consisting of max. 2 elements.
  • Page 12 Then attach the safety steel rope (parts list no 9) and secure it with the steel wire lock (no 10). Mount the motor housing with the motor on the extension element. Use the M16 x 120 mm screws for this. Pay attention to an exactly horizontal alignment. Note: The safety steel ropes must be aligned symmetrically for the same load, then tightened evenly, use the turnbuckles and a threadlocker glue at the end.
  • Page 13 Now assemble the fan blades. Use the M10 x 100 mm screws. Pay attention to an exact alignment of the rotor blades and use threadlocker glue. When assembling, make sure to connect all retaining brackets (parts list no.6) to each other. Then install the bottom plate (parts list no 8) with the screws M5 x 12 mm (no 7).
  • Page 14: Oil Check And Oil Safety Pin

    Nord Motor Wiring Clamps with a star bridge Wiring Fan Motor For the motor wiring, please remove the MonsterFans cover from the motor housing above the motor connection box. Then wire the motor in star cabling according to the connection diagram above.
  • Page 15: Frequency Converter

    Frequency Converter A frequency converter is located in the MonsterFans Controller Box. You will find detailed technical instructions from the manufacturer attached. The frequency converter is pre- programmed at the factory and is ready for operation. You will also find the following Wiring Diagram (3~400V, 50 Hz) printed inside the Controller Box.
  • Page 16: Commissioning

    Commissioning 6.1 Test Run Ideally, test the fan for 10 minutes to see if there is any unusual noise, vibration from the device or from the safety steel ropes. Also make sure that the fan runs safely with a sufficient safety distance to all possible obstacles.
  • Page 17: Troubleshooting

    6.3 Troubleshooting Common causes of incorrect operation: • The supply voltage is incorrectly selected or switched off. • If the fan does not work, please check first if the speed controller is at MIN and check also the Run/Stopp button. •...
  • Page 18: Warranty & Maintenance

    Warranty & Maintenance Our quality assurance applies to the entire fan. The warranty period begins on the date of acceptance by the customer after professional installation and commissioning. This ends with the statutory warranty period. The following causes are not covered by the warranty: 1.
  • Page 19: Packaging Units

    Packaging Units A MonsterFan is delivered in two wooden boxes. Picture: Wooden Box Fan Blades Picture: Wooden Box Motor Type Diameter Dimensions Weight Total MF-C24 7.3 m (24 ft.) Wooden box Motor: 180 kg 950 mm*830 mm*520 mm 307 kg Wooden box fan blades: 3700 mm*420 mm*450 mm 127 kg...
  • Page 20: Acceptance Report For Installation & Commissioning

    10 Acceptance Report for Installation & Commissioning Customer Order number Client Contact person Tel. E-mail Product type Number of Fans Serial number Fan height from the Local conditions floor, mounting height Distance to Ceiling height obstacles (top, bottom, side) Nominal voltage Current (A) Field voltage (V) Limit frequencies...
  • Page 21: Acceptance Report Of Maintenance

    11 Acceptance Report of Maintenance Customer Order number Client Contact person Tel. E-mail Product type Number of Fan Yearly maintenance 5-year maintenance Yearly maintenance Sign 1. Check the correct rotation of the fan. 2. Check all safety bracing devices. 3. Check all fastening screws and connecting elements. 4.
  • Page 22: Declaration Of Conformity

    12 Declaration of Conformity www.monsterfans.com info@monsterfans.com...
  • Page 23 Schwank GmbH - Bremerhavener Straße 43 - D-50735 Cologne Tel: +49 (0)221-7176-0 Fax: +49 (0)221-7176-288 www.monsterfans.com info@monsterfans.com www.monsterfans.com info@monsterfans.com...

Table of Contents