To connect the motor please remove the MonsterFans cover from the motor housing above
the motor terminal box and unscrew the cover from the motor terminal box. Lead the motor
connection cable through the EMC gland and pay attention to the position of the shielding
braid.
Figure: LAPP Skintop MS-SC EMC Cable Gland
For the motor wiring, please remove the MonsterFans cover from the motor housing above
the motor connection box. Then wire the motor in star cabling according to the connection
diagram above. The fan is operated exclusively with 3 phases, 400 volts AC.
Nord Motor Wiring

4.9 Oil Check and Oil Safety Pin

Please also check the oil level before starting up. There is a safety pin on the
bleed screw. The safety pin must be removed before the initial start-up. The
engine is operated with synthetic oil (lubricant: Synth ISO VG 680, 3.1 litres).
The safety pin is provided with a cable tie ex works to make the safety pin visible and to
make it easier to remove the safety pins.
www.monsterfans.com
Schematic Shielding Connection
Clamps with a Star Connection Stud
Wiring Fan Motor