8.3.9

Menu "Load current"

Fig. 34:
Load current
In this menu the current for the load to be switched is entered.
Value
Load current
Entering the load current
1. Select menu "Special functions".
2. Select menu "Load current".
The display shows the preset value.
3. Set the desired value with buttons "UP / DOWN".
This setting is configured in steps of 1 A.
4. Confirm your setting with the "OK" button.
Operating Instructions 2CKA001473B8822
Information
If high electric loads are controlled with the device, the high current heats up
the device and the displayed temperatures and the RH value are no longer
correct. With the entry of the load current, this value is used as the correcting
value of the displayed temperature and the relative humidity.
The load current can be set on the device between 1 ampere and 6
ampere in steps of 1 ampere.