USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 CONTENTS 1. OVERVIEW 2. WARRANTY 3. IDENTIFICATION 4. PRECAUTIONS 5. CLAUSES 6. TECHNICAL FEATURES 6.1. Chair 6.2. Dental Unit 7. TRANSPORT AND DIMENSIONS 8. DESCRIPTION OF THE DENTAL UNIT 8.1. Connections box 8.2.
Defects, intended damage or modifications caused by third parties unrelated to Ancar. Non-compliance with the maintenance periods specified in the User Manual or resulting from inadequate repair or maintenance that has not been carried out by an official Ancar technical service.
Page 5
In no case shall ANCAR be required to replace the entire unit or to reimburse its purchase price. ANTONI CARLES, S.A.'s responsibility and accountability for any damages shall cease in the following cases, whereby the warranty shall be automatically cancelled: 1.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL 3. IDENTIFICATION The identification label, which contains the technical information needed for connection, is folded. It can be seen from the rear of the seat and is also placed near the base, on the side of the chair.
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 PRESERVATION OF THE ENVIRONMENT All the materials used for packaging respect the environment and are recyclable: wooden pallet, cardboard, polyethylene bag and bubble film. Collection of the materials used favours recovery, recycling and reduction of waste material.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL 6. TECHNICAL FEATURES 6.1. Chair Ergonomic design for the patient. Chair movements powered by lifting gears that are silent and fully reliable. Movements controlled by a microprocessor: - Automatic return movement to the cuspidor.
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 7. TRANSPORT AND DIMENSIONS The dental unit is delivered perfectly packaged and protected. One box contains the dental chair attached to a pallet and the other two boxes contain the hydric box and whip arm system, respectively. (Figure 2) It is essential that none of these boxes undergo impacts during transport and they must not fall on the ground under any circumstance.
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 8.1. Connections box The connections box contains all the connections required to connect the dental equipment to the clinic's power supply, as well as the water and air adjustment components. Valve movement direction complies with standard UNE20128.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL 8.2. Electro-pneumatic pedal: This pedal is used for proportional adjustment of the optional instruments in the instrument tray: micromotor, turbine. Ultrasound On/Off (Fig. 5). Regulates the rotation speed of the electrical micromotor, turbine power and pneumatic micromotor by moving the handle (B);...
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 8.3. Instrument tray The tray has an ergonomic design to make work easier for the professional, as well as the following main features: - Control panel. - Capacity for up to 4 instruments.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL 8.4. Control panel CHAIR MOVEMENT FUNCTIONS - Safe movements integrated with activation of instruments using the regulating pedal. - Movement activation functions in conjunction with the regulating pedal (in this case there are no automatic movements, except for optional settings).
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 8.5. Headrest The hydric unit rotates approximately 70° in relation to the support arm, increasing ergonomic comfort for daily work. The upper part contains the tank support (A) and basin (B), made of porcelain to provide a high degree of hygiene (Figure 8).
A variety of dental hygiene specialists offer a wide range of cleaning products to achieve optimal results. ANCAR carries out systematic, comprehensive cleaning of its equipment before shipping with the disinfecting agent ECO-JET1 Spray by Magnolia (Cattani Group).
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 11. TECHNICAL DATA Voltage 230V Frequency 50 Hz Air pressure 5 Bar Water pressure 2.8 Bar Power 900 W Electrical protection class Type of operation Intermittent Maximum load (patient) 160 Kg.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL ANNEX 1. CLEANING AND DISINFECTION OF EQUIPMENT PARTS Cleaning and disinfection Carry out the operations with the device disconnected from the mains. Do not flood or wet the equipment with water.
Page 19
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 CE MARKING All products carry the CE marking. MANUFACTURING BATCH Each product is identified with an internal number placed at the end that identifies the exact production batch it belongs to. This number indicates the period of manufacture associated with the control card.
DENTAL UNIT A-3200 - REV.2 JULY 2020 USER MANUAL CLEANING AND STERILISATION After each intervention, the syringe should be cleaned and sterilised to guarantee maximum hygiene. Do so by taking the following steps: 135° - Remove the tip (unscrew the nose-tip terminal) and/or the entire grip (by pressing the button located at the bottom of the same and pressing upwards).
USER MANUAL DENTAL UNIT A-3200 - REV.2 JULY 2020 OBSERVATIONS ON ELECTROMAGNETIC INTERFERENCE Do not use the unit/chair in the presence of inflammable anaesthetic gas mixtures with oxygen or nitrogen protoxide. ANNEX 5. SYMBOL DEFINITIONS...
Page 22