GEH-62718 Installation Instructions
Power Break® II Circuit Breakers
Draw-Out BOD-4000 Ampere Frames

Advertisement

loading

Summary of Contents for GE Power Break II

  • Page 1 GEH-62718 Installation Instructions Power Break® II Circuit Breakers Draw-Out BOD-4000 Ampere Frames...
  • Page 3 Features may described herein that are not present in all hardware and software systems. GE Electrical Distribution & Control assumes no obligation of notice to holders of this document w i t h respect t o changes subsequently made.
  • Page 4: Table Of Contents

    Power Break® II Circuit Breakers Draw-Out Breaker Installation Table of Contents Description ..........................Features ........
  • Page 5: Description

    Power Break® II Circuit Breakers Draw-Out Breaker Installation Description Types SSD and SHD Power Break II draw-out circuit breakers are used in types SPS and SPH substructures, with appropriate catalog numbers listed in Table Draw·out construction permits activation of a n e w...
  • Page 7 Power Break® II Circuit Breakers Draw-Out Breaker Installation CAUTION: The breaker must be before it i s connected. If the breaker is charged, press the button to close the breaker contacts, then press the button to open the contacts. ATTENTION: Le disjoncteur doit etre en position avant qu'il ne soit embroche.
  • Page 8: Removing The Breaker

    Power Break® II Circuit Breakers Draw-Out Breaker Installation Removing the Breaker Use the following procedure to remove the draw-out :· breaker from the substructure. CAUTION: The breaker must be before it is dis­ connected and removed. ATTENTION: Le disjoncteur doit etre en position avant qu'il ne soit debroche et depose.
  • Page 9: Maintenance Procedures

    Power Break® II Circuit Breakers Draw-Out Breaker Installation A VERTISSEMENT: Avant commencer toute intervention sur des appareils debrochable, verifier que toutes les alimentations de puissance, la fois primaire et secondaire, sont coupees. Thoroughly clean the equipment by removing all dust and other accumulations. Wipe or vacuum clean buses...
  • Page 10 Power Break® II Circuit Breakers Draw-Out Breaker Installation frequent intervals. In this case, this procedure may not be sufficient and additional precautions may be necessary to protect the equipment. Lubrication All the areas subject to friction are liberally coated at the factory with Mobil 28 red grease.
  • Page 12 GE Electrical Distribution & Control General Electric Company 47 Woodford Ave., Plainville, CT 06062 © 7997 General Electric Company GE�62718 0697...