Timing Chart - Hitachi Kokusai Electric KP-F140F Specifications

Progressive scan ccd camera

Advertisement

6. Timing chart

a) Digital Out
Shutter time
Strobe output
(High active)
Data Output
VD Output
(Low active)
DATA
VD
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * aegisg2@aegiselect.com * http://www.aegis-elec.com
Shutter time
Strobe delay
(*1)
Strobe duration1
Strobe duration2
(*3)
3.2 ms (1280 x 960, Mono8, 15fps)
9H
(Camera setting value)
(*2)
7 / 12
Shutter time
(Camera setting
value)
(*1) 0.27~3930.51μs
(*2) 0.96~3931.2μs
(*3) Shutter Time – Strobe delay
(when duration time is set to 0)
0.96μs/step