6. Timing chart
a) Digital Out
Shutter time
Strobe output
(High active)
Data Output
VD Output
(Low active)
DATA
VD
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * aegisg2@aegiselect.com * http://www.aegis-elec.com
Shutter time
Strobe delay
(*1)
Strobe duration1
Strobe duration2
(*3)
3.2 ms (1280 x 960, Mono8, 15fps)
9H
(Camera setting value)
(*2)
7 / 12
Shutter time
(Camera setting
value)
(*1) 0.27~3930.51μs
(*2) 0.96~3931.2μs
(*3) Shutter Time – Strobe delay
(when duration time is set to 0)
0.96μs/step