Stiga stig Instruction Manual page 20

Table of Contents

Advertisement

3.3.3. MAIN VERIFICATIONS FOR THE INSTALLATION OF THE PERIMETER CABLE:
1. Check that the maximum slope of the work area is less than or equal to 45% (E) and observe the
rules shown in the images below:
a) if the slope is ≤ 20% the perimeter wire can be installed on it as shown in the image;
b) if the slope is > 20% and ≤ 45%, the installation must include the slope area observing the
distance indicated in the image;
c) if the slope is > 20% and the slope area is not part of the part of the garden to be cut, the
distance indicated in the image must be observed;
d) if the slope is > 45%, the slope area must be excluded observing the distance indicated in the
image.
a
E
c
20
3. INSTALLATION
E
E
b
E
d
EN