Chapter 4
Configuring the 6E3 Line Card
The following messages are associated with line card recovery:
Error Message 00:00:06:% LC-3-RECOVERY: Line card (slot <x>) recovery in progress
Error Message 00:00:06:% LC-3-EXCESSERRORS: Errors seen on the line card (slot %d)
exceeds the error threshold
When the 6E3 line card encounters any of the nonrecoverable errors listed below, the line card is
deactivated and must be restarted by performing a CLI-controlled OIR or physically removing and
installing the line card.
Line card hardware failures
Line card local processor boot code/firmware initialization failure (failure to boot or boot code
exceptions, firmware download failure)
Environmental critical conditions (voltage and temperature)
Insufficient system memory to allocate critical line card driver data structures during line card
initialization
The following examples show nonrecoverable fatal error messages:
Error Message 00:00:06% SERIAL-0-DLL_OUTOFLOCK: E3 HW DLLS failed to lock in line
card at slot <x>
Error Message 00:00:06% SERIAL-0-860_BOOT_NOTOK: E3 Line card local processor at
slot <x> failed to boot
Error Message 00:00:06% SERIAL-3-FW_CHECKSUM_FAILED: E3 line card in slot <x>,
firmware integrity check failed (section <x>, expected checksum: <x>, calculated
checksum: <x>)
Error Message 00:00:06% ENVM-0-SHUTDOWN: Environmental Monitor initiated shutdown
due to <voltage/temperature/power supply> in slot <x>
Error Message 00:00:06% SERIAL-1-ALLOCFAIL: E3 (slot <x>) line card plugin structure
allocation failure
OL-5061-01
Cisco 7304 6-Port Clear Channel E3 Line Card Installation and Configuration
Line Card Crash Recovery
4-19