Download Print this page

Chapter 4 - Display Programming - Garnet SeeLevel Access T-DP0301-B Manual

Data portal & remote display with 4-20 ma output and serial interface

Advertisement

CHAPTER 4 - DISPLAY PROGRAMMING

T
he S
the information shown on the 806-B, 806-Bi, 808-P2 or
810-PS2 gauge. The 4-20 mA analog output is calculated from the
display level with a 4 mA output corresponding to a display level
of zero, and a 20 mA output corresponding to the full scale level
programmed into the S
For example, if the full scale is programmed to be 500.0, then a
display value of 400.0 will result in an analog output of 16.80 mA.
The display will recognize the decimal location and adjust the
output accordingly, so in this example a display value of 400 will
also result in an analog output of 16.80 mA.
To set the full scale level:
1. Determine the maximum volume that can be displayed and
pick a full scale amount that is equal to or greater than this
volume.
2. Press both the NEXT MENU and UP/ENTER buttons on the
back panel, the display will show ACAL. Release both buttons.
3. The display will show the existing calibration with the left digit
bright. Press the UP/ENTER button to change the bright
digit. Press the NEXT MENU button to go to the next digit.
4. Set all 4 digits, then press NEXT MENU again to set the
decimal point, it will be bright to indicate that it is selected.
Press the UP/ENTER button to select either x.xxx, xx.xx, xxx.x
or no decimal. For best accuracy of the analog output, try to
use all 4 digits such as 500.0 instead of just 500.
5. After the decimal as been set, press NEXT MENU again,
the display will show Stor. Press UP/ENTER to store the
calibration and exit the setting menu. The display will continue
to show Stor for a moment and then will show donE for a
second. Then normal operation resumes.
6. If you do not want to store the calibration, press NEXT MENU
again and the display will show Abrt. Press UP/ENTER to
abort which exits the calibration menu without saving.
7. If you press NEXT MENU again from the Abrt display, the
menu will return to the beginning with the left digit selected
by being bright.