Wiring and Auto Recognition
COMPLETE STEPS 1-8
Step 1) Unplug the receiver from the wire harness.
Step 2) Wire the Red, Black, Yellow and Green to the keypad.
RED
Connect to Keypad Red or Aux (+)
BLACK
Connect to Keypad Black or Aux (-)
GREEN
Connect to Keypad Green
YELLOW
Connect to Keypad Yellow
*Moose ZX200/400/900/950 Connect to the White wire.
NOTE: You can make these connections at the panel or at the keypad
itself. If you place the Code Encryptor II in the garage or any other
location away from the panel you may choose to wire the Code
Encryptor II directly to the keypad.
Step 3) Make sure the alarm panel is powered up and operating.
Step 4) While watching the LED light on the Control module, plug the receiver into
the Code Encryptor II harness.
Step 5) The LED will blink 1 time on power up, after 2 seconds COUNT the flashes
that you see. The corresponding flashes will indicate which panel the Code
Encryptor II has detected.
*If you are using a DSC 1550 or a Caddx 8980E see page 16.