Honeywell Code Encryptor II Installation Manual page 16

Hide thumbs Also See for Code Encryptor II:
Table of Contents

Advertisement

DEFAULT MODE:
• If the Code Encryptor II fails to recognize any of the data coming from the keypad
wires, it will automatically default to a relay mode for button #1
• If this happens, verify that you are properly wired to one of the alarms listed on
page 5.
• If you have connected the CE II to an alarm it does not recognize, follow the
wiring below for a keyswitch mode.
• Program a selected zone as "Keyswitch Arming."
• Do not use the green or yellow wires.
Installation for Keyswitch Arming
Red
Aux +
Black
Aux -
Brown/White Zone programmed for keyswitch arming
Brown
Common adjacent to zone
Zone programmed
for keyswitch arming
Resistor should be in-line OR across
the zone, whichever clears the zone.
Alarm Panel
Black
Red
Brown
CODE
ENCRYPTOR
Brown/White
15