Periodic Maintenance; Cleaning The Squeegee Tube; Cleaning The Solution Tank And Filter - Fimap GENIE B Use And Maintenance Manual

Hide thumbs Also See for GENIE B:
Table of Contents

Advertisement

1. CLEANING THE SQUEEGEE TUBE

Periodically, or whenever suction seems to be unsatisfactory, verify that the squeegee tube is not
obstructed. To clean it, proceed as follows:
1. Remove the tube from the sleeve on the squeegee
2. Remove the other end from the recovery tank
3. Wash the inside of the tube with a water jet introduced from the side where it is connected to the tank
4. Re-assemble the tube.
ATTENTION: Do not wash the tube running between the suction unit and the
suction cap

2. CLEANING THE SOLUTION TANK AND FILTER

1. Detach the quick connection (1) to avoid breaking the connection itself.
2. Remove the solution tank.
3. Unscrew the filler cap (2).
4. Remove the filter and clean it (3).
5. Rinse the tank and clean with a jet of water.
6. Re-assemble the tank, carrying out the above operations in the reverse order.
7. Reassemble the filter and cap.
ATTENTION: Before carrying out any type of maintenance, disconnect the
machine's battery connector.
ATTENTION: This operation must be carried out wearing gloves to protect
against contact with dangerous solutions.