Install The Protector System - Chamberlain Power Drive Security+ HD400D Owner's Manual

Chamberlain power drive hd400d garage door openers: user guide
Hide thumbs Also See for Power Drive Security+ HD400D:
Table of Contents

Advertisement

INSTALLATION STEP 10

Install The Protector System

The safety reversing sensor must be connected
and aligned correctly before the garage door
opener will move in the down direction.
IMPORTANT INFORMATION ABOUT THE SAFETY
REVERSING SENSOR
When properly connected and aligned, the sensor
will detect an obstacle in the path of its electronic
beam. The sending eye (with an amber indicator
light) transmits an invisible light beam to the
receiving eye (with a green indicator light). If an
obstruction breaks the light beam while the door is
closing, the door will stop and reverse to full open
position, and the opener lights will flash 10 times.
The units must be installed inside the garage so that
the sending and receiving eyes face each other
across the door, no more than 6" (15 cm) above the
floor. Either can be installed on the left or right of the
door as long as the sun never shines directly into the
receiving eye lens.
The mounting brackets are designed to clip onto the
track of sectional garage doors without additional
hardware.
Safety Reversing Sensor
6" (15 cm) max. above floor
Facing the door from inside the garage
®
If it is necessary to mount the units on the wall, the
brackets must be securely fastened to a solid surface
such as the wall framing. Extension brackets (see
accessories) are available if needed. If installing in
masonry construction, add a piece of wood at each
location to avoid drilling extra holes in masonry if
repositioning is necessary.
The invisible light beam path must be unobstructed.
No part of the garage door (or door tracks, springs,
hinges, rollers or other hardware) may interrupt the
beam while the door is closing.
Invisible Light Beam
Protection Area
20
WARNING
Be sure power is not connected to the garage door
opener BEFORE installing the safety reversing sensor.
CAUTION
To prevent SERIOUS INJURY or DEATH from a closing
garage door:
• Correctly connect and align the safety reversing
sensor. This required safety device MUST NOT be
disabled.
• Install the safety reversing sensor so beam is NO
HIGHER than 6" (15 cm) above garage floor.
Safety Reversing Sensor
6" (15 cm) max. above floor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Security+ powerdrive pd212dSecurity+ powerdrive pd210d

Table of Contents