Install The Protector System - Chamberlain HD220C Manual

Chain drive garage door opener
Hide thumbs Also See for HD220C:
Table of Contents

Advertisement

Available languages

Available languages

Installation
STEP 13 Install the Protector System
Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing
sensor.
To prevent SERIOUS INJURY or DEATH from closing garage door:
Correctly connect and align the safety reversing sensor. This required safety device MUST NOT
l
be disabled.
Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
l
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSORS
The safety reversing sensors must be connected and aligned correctly before the garage door
opener will move in the down direction.
The sending sensor (with an amber LED) transmits an invisible light beam to the receiving sensor (with a
green LED). If an obstruction breaks the light beam while the door is closing, the door will stop and
reverse to the full open position, and the garage door opener lights will flash 10 times.
NOTE: For energy efficiency the garage door opener will enter sleep mode when the door is fully
closed. The sleep mode shuts the garage door opener down until activated. The sleep mode is
sequenced with the garage door opener light bulb; as the light bulb turns off the sensor LEDs will turn off
and whenever the garage door opener lights turn on the sensor LEDs will light. The garage door opener
will not go into the sleep mode until the garage door opener has completed 5 cycles upon power up.
When installing the safety reversing sensors check the following:
Sensors are installed inside the garage, one on either side of the door.
l
Sensors are facing each other with the lenses aligned and the receiving sensor lens does not
l
receive direct sunlight.
Sensors are no more than 6 inches (15 cm) above the floor and the light beam is unobstructed.
l
Invisible Light Beam
Protection Area
Facing the door from inside the garage
®
Safety Reversing Sensor
6" (15 cm) max. above floor
Carriage Bolt
1/4"-20x1/2"
The safety reversing sensors can be attached to the door track, the wall, or the floor. The sensors should
be no more than 6 inches (15 cm) above the floor. If the door track will not support the sensor bracket a
wall installation is recommended. Choose one of the following installations.
OPTION A
DOOR TRACK INSTALLATION
1. Slide the curved arms of the sensor bracket around the edge of the door track. Snap into place
so that the sensor bracket is flush against the track.
2. Slide the carriage bolt into the slot on each sensor.
3. Insert the bolt through the hole in the sensor bracket and attach with the wing nut. The lenses on
both sensors should point toward each other. Make sure the lens is not obstructed by the sensor
bracket.
1
No more
than 6 inches
(15 cm)
20
HARDWARE
Wing Nut
1/4"-20
2
3
Carriage Bolt
1/4"-20x1/2"
Wing Nut
1/4"-20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd220Pd220Pd222Lw260c

Table of Contents