Elkay 4592 FTN Series Owner's Manual
Elkay 4592 FTN Series Owner's Manual

Elkay 4592 FTN Series Owner's Manual

Wall mount stone fountains

Advertisement

Quick Links

Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation,
leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS,
ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE
BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH
CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY
DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
4592_FTN
4593_ FTN
Owners Manual
Wall Mount Stone Fountains
IMPORTANT
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 1
PAGE 1
WWW.RESTROOMDIRECT.COM
LK4593_FTN
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE IS
TUBE TO ATTACH
SECURED
IN POSITION
704 • 937• 2673
129 Oakpark Dr., Unit A, Mooresville, NC 28115
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
97215C (Rev. SIE - 1/11)

Advertisement

loading

Summary of Contents for Elkay 4592 FTN Series

  • Page 1 4592_FTN 4593_ FTN LK4593_FTN Owners Manual Wall Mount Stone Fountains Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
  • Page 2 4592_FTN 4593_FTN LK4593_FTN 4592 ROUGH-IN LEGEND: A = RECOMENDED WATER SUPPLY LOCATION, 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL SHUT OFF VALVE BY OTHERS. B = RECOMMENDED LOCATION FOR WASTE OUTLET, 1-3/4" O.D. (44mm) DRAIN. C = (4) 5/16"...
  • Page 3 4592_FTN 4593_ FTN LK4593_FTN 4593 ROUGH-IN LEGEND: A = RECOMENDED WATER SUPPLY LOCATION, 3/8" O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL SHUT OFF VALVE BY OTHERS. B = RECOMMENDED LOCATION FOR WASTE OUTLET, 1-3/4" O.D. (44mm) DRAIN. C = (4) 5/16"...
  • Page 4 4592_FTN 4593_FTN LK4593_FTN ITEMIZED PARTS LIST ITEM PART NO. DESCRIPTION 100147140560 Drain Gasket 100322740560 Bubbler Gasket 101570540560 Drain Gasket 15005C Regulator Retaining Nut 15013C Bubbler Tube Assy. 170705042830 Basin 40048C Button 40089C Nut - Cover 400942308640 Bubbler 98287C Bubbler Assembly 40169C Hex Nut 1-5/16"-20UN 50986C...