4595 Freeze Resistant Pedestal Barrier Free Stone Fountain
PLEASE READ THE FOLLOWING
• INSTALLATION INSTRUCTIONS FOR THE 4595FR FTN.
WITH 97482C DUAL VALVE CONTROL ASSEMBLY ARE
LOCATED ON PAGES 2 - 5.
• INSTALLATION INSTRUCTIONS FOR THE 4595FR FTN.
WITH SANITARYFR2 VALVE ARE LOCATED ON PAGES
6 - 12.
INSTALLER
4595FR Fountains are among the easiest to install Fountains on the market today. To assure
you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A
COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS
GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A
METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF
PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
4595FR_FTN LK4595FR_FTN LK4595SFR_FTN
Owners Manual
STOP!
INFORMATION.
IMPORTANT
IMPORTANT
PAGE 1
97461C (Rev. SIC - 1/11)

Advertisement

loading

Summary of Contents for Elkay 4595FR

  • Page 1 6 - 12. INSTALLER 4595FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.
  • Page 2 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN Owners Manual 4595 Freeze Resistant Barrier Free Stone Pedestal Fountain with 97482C Dual Valve Control Assembly IMPORTANT! INSTALLER PLEASE NOTE Do not pull up on lines coming out of the PVC column. This raises the water valve above the frost line with disastrous results.
  • Page 3 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN SITE PREPARATION DETAIL FOR THE 4595FR FTN. WHEN USING 97482C DUAL VALVE CONTROL ASSY. LEGEND F = 1-1/4" DRAIN TUBE A = ACCESS PANEL G = AIR CONTROL LINE B = REMOVABLE BOTTOM COVER C = 1" PVC DRAIN H = 1/4"...
  • Page 4: Troubleshooting

    4595FR_FTN LK4595FR_FTN LK4595SFR_FTN INSTALLATION INSTRUCTIONS FOR INSTALLING 97482C DUAL VALVE CONTROL ASSY. 1. Prepare trench for water supply and waste drain lines (if required by local codes). The hole should be deep enough to accommodate the PVC column and 5 cubic feet of porous fill (large broken rock).
  • Page 5 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN The following items are included with the 4595FR Fountain PARTS LIST 10-A, 6 ITEM NO. PART NO. DESCRIPTION 100147140560 Drain Gasket 100322740560 Gasket 101449542550 Clamp - Hose 10-B 101570540560 Drain Gasket 15013C Bubbler Tube Assy. 110544942550 Set Screw #8-32 x .125...
  • Page 6: General Installation Tips

    4595FR_FTN LK4595FR_FTN LK4595SFR_FTN Owners Manual 4595 Freeze Resistant Barrier Free Stone Pedestal Fountain with SanitaryFR2 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1.
  • Page 7 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4595FR FTN. WHEN USING THE SANITARYFR2 VALVE FIG. 1 PAGE 7 97461C (Rev. SIC - 1/11)
  • Page 8 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4595FR FTN. WHEN USING THE SANITARYFR2 VALVE 1-1/2 DRAIN TUBE SUPPLIED WITH FTN. AIR GAP ASSY. SUPPLIED WITH VALVE 1-1/2 DRAIN TUBE SUPPLIED BY INSTALLER Detail A FIG. 2 LEGEND A = ACCESS PANEL B = REMOVABLE BOTTOM COVER 97461C (Rev.
  • Page 9 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S) Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A & B) into the connector(s) (provided with fountain). Insert the 1/8” O.D.
  • Page 10 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN Stream Height Adjustment 5, 13 FIG. 5 FIG. 4 SEE DETAIL B DETAIL B FIG. 6 97461C (Rev. SIC - 1/11) PAGE 10...
  • Page 11: Parts List

    4595FR_FTN LK4595FR_FTN LK4595SFR_FTN The Following Items are included with the SanitaryFR2 Valve PARTS LIST PART NO. DESCRIPTION ITEM NO. 110175443890 Hex Nut - 3/8-16 28424C Bracket - Regulator Holder 40045C Hex Nut - 1-5/16 45807C Dual Valve 50986C Regulator Holder 56082C Regulator Nut 56092C...
  • Page 12 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN The Following Items are included with the 4595FR Fountain PARTS LIST ITEM NO. PART NO. DESCRIPTION 28-A, 24 100147140560 Drain Gasket 100322740560 Gasket 101570540560 Drain Gasket 15013C Bubbler Tube Assy. 110544942550 Set Screw #8-32 x .125 110868642550 Socket Head Screw #10-24 x .75...

This manual is also suitable for:

Lk4595frLk4595sfr