Elkay 4420 Owner's Manual

Elkay 4420 Owner's Manual

Freeze resistant tubular fountain with dual valve control assembly
Hide thumbs Also See for 4420:

Advertisement

Quick Links

4420FR_FTN
LK4420FR_FTN
Owners Manual
4420 Freeze Resistant Tubular Fountain
with 97482C Dual Valve Control Assembly
INSTALLER
4420FR Fountains are among the easiest to install Fountains on the market today. To assure
you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.
PAGE 1
97734C (Rev. P - 01/17)

Advertisement

Table of Contents
loading

Summary of Contents for Elkay 4420

  • Page 1 4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with 97482C Dual Valve Control Assembly INSTALLER 4420FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
  • Page 2: Installation Instructions

    4420FR_FTN LK4420FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
  • Page 3 4420FR_FTN LK4420FR_FTN PAGE 3 97734C (Rev. P - 01/17)
  • Page 4 4420FR_FTN LK4420FR_FTN SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING 97482C DUAL VALVE CONTROL ASSY. PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER FIG. 1 O 14" 356mm 29"...
  • Page 5: Troubleshooting And Maintenance

    4420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE TROUBLE SHOOTING Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
  • Page 6 45971C Dual Control Valve Assy. 45788C Rainbird Check Valve 28703C Blank Nameplate Insert (only) 28703C-LK Elkay Nameplate Insert (only) 28091C-HT Halsey Taylor Nameplate Insert (only) 56092C Poly Tubing - 1/4" (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8"...
  • Page 7: General Installation Tips

    4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with SanitaryFR2 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1.
  • Page 8 4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 4" PVC 1/4 BEND 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS 4"...
  • Page 9 4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 1-1/2 DRAIN TUBE SUPPLIED WITH FTN. ( 6 ) 1/2" ( 13mm ) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER AIR GAP ASSY.
  • Page 10 4420FR_FTN LK4420FR_FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S) Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A & B) into the connector(s) (provided with fountain). Insert the 1/8” O.D.
  • Page 11 4420FR_FTN LK4420FR_FTN Stream Height Adjustment 5, 13 FIG. 5 FIG. 4 SEE DETAIL B DETAIL B FIG. 6 PAGE 11 97734C (Rev. P - 01/17)
  • Page 12: Parts List

    4420FR_FTN LK4420FR_FTN The Following Items are included with the SanitaryFR2 Valve PARTS LIST PART NO. DESCRIPTION ITEM NO. 110175443890 Hex Nut - 3/8-16 28424C Bracket - Regulator Holder 40045C Hex Nut - 1-5/16 45807C Dual Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4”...
  • Page 13 4420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE Trouble Shooting Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
  • Page 14 Brown = BRN Red = RED PRINTED IN U.S.A. FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816 Halsey Taylor – halseytaylor.com Elkay – elkay.com 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523 97734C (Rev. P - 01/17) PAGE 14...