4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with 97482C Dual Valve Control Assembly INSTALLER 4420FR Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
4420FR_FTN LK4420FR_FTN INSTALLATION INSTRUCTIONS IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER.
Page 4
4420FR_FTN LK4420FR_FTN SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING 97482C DUAL VALVE CONTROL ASSY. PVC COLUMN CENTERED BETWEEN MOUNTING BOLT HOLES (6) 1/2" (13mm) DIA. HOLES EQUALLY SPACED ON A 12" (305mm) BOLT CENTER FIG. 1 O 14" 356mm 29"...
4420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE TROUBLE SHOOTING Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
4420FR_FTN LK4420FR_FTN Owners Manual 4420 Freeze Resistant Tubular Fountain with SanitaryFR2 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1.
Page 8
4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 4" PVC 1/4 BEND 1-1/2" DRAIN TUBE (SUPPLIED BY INSTALLER) (SUPPLIED BY INSTALLER) 4" PVC PIPE (SUPPLIED BY INSTALLER) CONCRETE SLAB CLEANOUT PLUG FOR ACCESS 4"...
Page 9
4420FR_FTN LK4420FR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4420FR FTN. WHEN USING THE SANITARYFR2 VALVE 1-1/2 DRAIN TUBE SUPPLIED WITH FTN. ( 6 ) 1/2" ( 13mm ) DIA. HOLES EQUALLY SPACED ON A 12" ( 305mm ) BOLT CENTER AIR GAP ASSY.
Page 10
4420FR_FTN LK4420FR_FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN(S) Step 1 - Insert the 1/8” O.D. tube(s) (Labeled A & B) into the connector(s) (provided with fountain). Insert the 1/8” O.D.
Page 11
4420FR_FTN LK4420FR_FTN Stream Height Adjustment 5, 13 FIG. 5 FIG. 4 SEE DETAIL B DETAIL B FIG. 6 PAGE 11 97734C (Rev. P - 01/17)
4420FR_FTN LK4420FR_FTN The Following Items are included with the SanitaryFR2 Valve PARTS LIST PART NO. DESCRIPTION ITEM NO. 110175443890 Hex Nut - 3/8-16 28424C Bracket - Regulator Holder 40045C Hex Nut - 1-5/16 45807C Dual Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4”...
Page 13
4420FR_FTN LK4420FR_FTN TROUBLE SHOOTING AND MAINTENANCE Trouble Shooting Insufficient Bubbler Flow: Check that the shut-off valve is wide open. Verify minimum 20 PSI supply pressure. Clean inlet strainer screen located in the valve body. Clean rubber orifice in flow control located below frost line in bushing between barb fitting and valve. No Flow: Check for leaks in the air tubing going from the push button to the valve. Make sure the air tubing compression nut is hand tight. Disconnect air tube from push button. Place finger over air outlet. Push button to test diaphragm. Tighten diaphragm cap screws. Replace diaphragm if necessary.
Page 14
Brown = BRN Red = RED PRINTED IN U.S.A. FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816 Halsey Taylor – halseytaylor.com Elkay – elkay.com 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523 97734C (Rev. P - 01/17) PAGE 14...