ERROR CODE
Failure
Failure Type
Code
F01
Probe
F02
Temperature
F03
EEPROM
F04
WIDE
F05
Latch
(Pyro version only)
F06
Door
(Pyro version only)
F07
Cooking parameter data
set error.
F08
UI EEPROM
F09
UI SPI memory error
F10
Function Knob error
F11
6th Sense error
F18
Zero crossing error
F20
FPGA error (only Atlas)
F21
HMI input error (only
Atlas)
Service Manual UK
Suggested Repair Action
Temperature Probe error.
First check probe connection, if ok disconnect the probe and measure its
resistance (1000 +3.75* Temp ambient). If value is in range check AM.
Temperature error.
Check heating elements insulation (disconnect the heating element and
check each terminal for continuity to EARTH).
If there is no continuity change AM.
If there is continuity change heating element.
EEPROM error.
Check with the manual configuration menu that the oven is correctly
configured and the test bit is set to ON. Wait 10 minutes.
If F03 appears again, change AM.
WIDE communication error.
First check the connection on P007. If it is OK check the connection of the
WIRE that start from AM P007 to the UI board. If it is OK connect a new UI
and check if the appliance works properly. If not change the AM.
Latch error.
First unplug the appliance, wait at least 10 seconds the reconnect. Verify that
latch system repositioning work correctly (door has to be closed, motor has
to run). If this happens, check the connection between AM and door latch
system. If it is OK check microswitch functionality (door switch open if the
door is open and latch switch open if the door is unlocked). If switches are OK
then change AM.
Door error.
First check connection between AM and door latch system. If it is OK check
door switch functionality (open circuit if door is open, closed circuit if the door
is closed). If switch is OK then change AM.
Data set error.
If the system persists change AM.
User Interface EEPRO< error.
Change IU (Navigator or Atlas).
UI SPA memory error.
Change UI (Navigator or Atlas).
The value read is not allowed for the selected knob.
First check connection between UI (dummy or smart) and the knob. If it is OK,
check that the oven is correctly configured using the manual configuration
menu. If the problem persists change the knob encoder. If the problem still
persists, change the AM.
6th Sense error, voltage error or current error.
Verify power supply voltage is 230 +/- 10%.
If supply is within tolerances, change AM.
Not foreseen.
Change UI.
Change UI.