6. Assembly HSG ILL Module:
6.1 CM Assembly
I.
Insert "Clip CM Side" first, and then place "Clip Front CM" to fixed-shaft of ILL SUB
before locking screw (Fig. 6-1, Fig. 6-2).
II. Assemble CM to HSG ILL and to make CM contact three datum on the HSG ILL
Well (Fig. 6-3).
III. Assemble "CLIP TOP CM" (with forceps) to the "HSG IL" (Fig. 6-4,).
IV. To check and make sure "CLIP of CM" hooks the HSG ILL very Well (Fig. 6-5).
V. Paste "Sponge tube AL" on cannelure of " HSG ILL" (Fig. 6-6).
6.2 FM Module Assembly
I.
FM Module must be placed to fixed shaft and on the datum surface of "ILL SUB" and
then lock with screw well (Fig. 6-7).
Clip CM Side
Datum1
Fig. 6-1
Fig. 6-2
Fig. 6-3
62
Fixed shafts
of ILL SUB
Screw
8F.1A752.3R0
Datum3
Datum2