BenQ MP512 Product Service Manual page 58

Hide thumbs Also See for MP512:
Table of Contents

Advertisement

4. Assembly LP module:
4.1 LP must datum well with "BKT_LP" show as Fig. 4-1.
4.2 Referring to Fig. 4-2, it must be visible clearance between "BKT_LP" and "LP Opening" after
assembling.
Bottom
Datum
4.3 Glue "LP" and "BKT_LP" with "UV5503 Glue" at two opening of "BKT_LP" show in Fig. 4-3.
4.4 UV-5503 Glue curing process and concerns:
i.
The UV-glue must fill up the whole opening area (shown in Fig. 4-3) to contact well with
LP surfaces and "BKT_LP".
ii.
Exposed to visible light at 350 ~ 420nm(at least 100mW/cm2) wavelength for 1 minute.
iii. After curing, the height of UV-glue should not exceed BKT_LP for more than 0.6mm.
Glue 5503
Fig. 3-2
Right Datum
Fig. 4-1
58
Fig. 4-2
Fig. 4-3
Clearance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9h.y1277.000

Table of Contents