OUPut:PONSetup <RST|LAST|LOFF>
This command controls the settings and output state when the power supply is
powered on.
Syntax
OUTPut:PONSetup <RST|LAST|LOFF>
Arguments
<RST|LAST|LOFF>
Default value
RST
Example
OUTP:PONS LAST
Query syntax
OUTPut:PONS?
Returns
RST|LAST|LOFF

OUTPut:REVerse[:STATe]?

This command is used to query the connection of output terminals.
Syntax
OUTPut:REVerse[:STATe]?
Arguments
None
Default value
None
Example
OUTP:REV?
Returns
0|1