Start-up and operation

6
Start-up and operation
Observe the safety instructions in chap. Safety, from page 5 on.
Please refer to chap. Technical data, page 7 for permissible operating
Permissible
conditions.
operating
conditions
Standard
For all NVV, use a ball valve to shut off the main line and
installation
• a maintenance unit with mist lubricator for NVV 150,
• a filter regulator for all other types of NVV (with an integrated mist lu-
Use the pressure control valve of the filter regulator/maintenance unit to
Setting the
set the operating frequency of the NVV.
frequency
By reducing the operating pressure, the centrifugal force is also reduced.
At the same time the vibration amplitude remains almost constant.
Filling mist
Fill the lubricator body with approx. 60 ml of oil corresponding to the per-
lubricator
missible operating conditions (see page 7; "Lubrication").
Notice: The NVV is ready for operation only after filling and correct func-
tioning of the mist lubricator.
Initial
Before initial start-up, also pour 4-6 drops of oil onto the sieve of the claw
lubrication
coupling of the NVV.
Procedure
When starting-up the NVV carry out the following steps in succession:
1.
2.
3.
4.
5.
Tap to start
If the NVV does not start, the vibrator's nosepiece should be briefly tapped
onto a firm surface.
bricator).
Close the ball valve.
Close the manual (slide) valve of the NVV. For NVV 28 - 100, turn the
manual valve clockwise while looking at the claw coupling.
Connect the claw coupling.
Open the ball valve.
Open the manual (slide) valve, for NVV 28 - 100 by turning it anti-
clockwise.