Charnwood ISLAND II-BP Operating & Installation Instructions Manual

Charnwood ISLAND II-BP Operating & Installation Instructions Manual

Hide thumbs Also See for ISLAND II-BP:

Advertisement

Quick Links

®
II - BP
Operating & Installation Instructions
AUSTRALIA

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood ISLAND II-BP

  • Page 1 ® II - BP Operating & Installation Instructions AUSTRALIA...
  • Page 3: Table Of Contents

    INSULATED ROOM SEAL FLUE KIT INSULATED ROOM SEAL FLUE KIT INSULATED ROOM SEAL FLUE KIT COMPLIANCE DATA ISLAND II - BP DIMENSIONS ISLAND II - BP PARTS LIST CHARNWOOD AUSTRALIA 10 YEAR GUARANTEE 23 Ref.island ii - bp aus v1 12.20...
  • Page 4: Quick Guide

    Boost Nominal AIR CONTROL SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Liquid fuel Household waste Coal singles Add kindling and paper or...
  • Page 5: Operating Instructions

    Charnwood. Log moisture content of less than 20% is recommended. The Charnwood Island II - BP is fitted with an air control stop. This PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS stops the stove from burning too slowly.
  • Page 6: Wood Ash Removal Grate

    Too much riddling can result in emptying Your Charnwood Island II - BP is fitted with a wood ash removal unburnt fuel into the ashpan and should therefore be avoided. After grate to enable wood to be burned and ash to be cleared.
  • Page 7: Ash Clearance

    For reduced burning the fire door must be closed. only be carried out by the Manufacturer or their approved agents. Use only genuine Charnwood replacement parts. When burning wood in areas that are not smoke controlled, load some large logs on the fire and allow to burn for half an hour before...
  • Page 8: Flue Sweeping

    The airwash relies on a supply of heated air to keep the glass clean, therefore, when lighting the stove allow the firebed to become well Your Charnwood flue should be swept at least twice a year. Where established before closing the air control. This may also be necessary the top outlet or vertical rear flue connector is used it will generally when re-fuelling the stove.
  • Page 9: If You Need Further Help

    If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local Charnwood Dealer has a great deal of experience and will also be able to provide helpful advice. Further help is available from Pivot...
  • Page 10: Installation Instructions

    If a wooden mantelpiece or beam is used in the fireplace External air supply kits are available please contact Charnwood for it should be a minimum of 460mm (18”), and preferably 600mm more information. Instruction sheet ref: TIS 120 (24”) from the appliance.
  • Page 11: Connections To Flues

    INSTALLATION INSTRUCTIONS ® In order for the fire to operate correctly the rear air inlet must not The kit comprises of a cooking plate and four trivets and can only be be obstructed. fitted to the stove if a rear flue connection is made. The appliance should be installed on a floor with adequate load- bearing capacity.
  • Page 12: Clearances

    CLEARANCES ® PARALLEL POSITION CORNER POSITION COMBUSTIBLE WALLS ISLAND II - BP Standard Clearance Corner Clearance 225mm 275mm 385mm 578mm 450mm 757mm...
  • Page 13: Standard Hearth Dimensions

    STANDARD HEARTH DIMENSIONS ® DEFAULT HEARTH TO WALL VERTICAL REAR FLUE ADAPTOR ISLAND II - BP VERTICAL REAR FLUE ADAPTOR MIN. DIMENSIONS DEFAULT HEARTH MIN. DIMENSIONS TO WALL MIN. DIMENSIONS TO WALL 900mm 1125mm 1158mm 875mm 875mm 875mm 470mm 470mm 470mm 275mm 275mm...
  • Page 14: Corner Hearth Dimensions

    CORNER HEARTH DIMENSIONS ® VERTICAL REAR FLUE ADAPTOR Minimum dimensions to wall Minimum dimensions to wall ISLAND II - BP CORNER HEARTH WITH VERTICAL REAR FLUE ADAPTOR 875mm 875mm 578mm 578mm 470mm 470mm 458mm NON-COMBUSTIBLE MATERIAL Minimum thickness: 24mm Minimum thermal resistivity: 0.052 Installed in accordance with AS/NZS 2918:2018 3.3.2...
  • Page 15: Flue Clearances Diagram

    FLUE CLEARANCES DIAGRAM ® Summary of minimum height of flue sytem exit requirements from AS/NZS 2918:2018 6000 3000 More than 3000 or less 600 min. 3000 1000 min. if clear within 3000 of flue top Increase as necessary until nothing within 6000 of flue top Any nearby structure More than 3000 3000...
  • Page 16: Standard Default Triple Skin Flue Kit

    STANDARD DEFAULT TRIPLE SKIN FLUE KIT ® Cowl Flashing Optional 1000 Triple skin flue 1000 Ceiling Ring Dropbox 1000 Decorative Flue Solid OR Mesh 1000...
  • Page 17: Insulated Room Seal Flue Kit

    INSULATED ROOM SEAL FLUE KIT ® STANDARD FLUE KIT Cowl Room sealed flue (with locking band) 1000 Starter length flue 1000 Ceiling ring Room sealed flue adaptor 1000 Single skin flue Heatshield...
  • Page 18: Insulated Room Seal Flue Kit

    INSULATED ROOM SEAL FLUE KIT ® FULLY SEALED FLUE KIT Cowl Room sealed flue (with locking band) 1000 Starter length flue 1000 Ceiling ring 1000 Heatshield 1000...
  • Page 19: Insulated Room Seal Flue Kit

    INSULATED ROOM SEAL FLUE KIT ® REAR FLUE KIT Cowl Room sealed flue (with locking band) 1000 Gutter Wall Penetration Roof support brace min 25 Adjustable wall bracket Wall Plate Cleaning access Wall plate gal NOTE: 2700 There needs to be 50mm clearance to any timber above the flue pipe and a 25mm clearance to any timber to the side and underneath.
  • Page 20: Compliance Data

    COMPLIANCE DATA ® ISLAND II - BP - COMPLIANCE DATA Compliance plate riveted onto rear heatshield...
  • Page 21: Island Ii - Bp Dimensions

    ISLAND II - BP DIMENSIONS ® To suit 150mm (6”) flue pipe PLAN VIEW Optional rear flue adaptor FRONT SIDE REAR...
  • Page 22: Island Ii - Bp Parts List

    Charnwood Island II (BP-Australia) Parts List ISLAND II - BP PARTS LIST Issue A ® Item Part No. Description Item Part No. Description 008/BP035 Door Seal Set Inc. Adhesive 004/AP051 Tool Holder 008/FW29 Door Seal Adhesive 008/BP110 Air Control Gasket...
  • Page 23: Charnwood Australia 10 Year Guarantee

    • The following conditions apply: • If any part fails due to manufacturing or material defect within the guarantee period Charnwood will, free of charge, either repair or replace the part at their discretion. The decision of Charnwood is final.
  • Page 24 your premier dealer...

Table of Contents