Lamp Switch Card ConnectionsFigure 16 details the connections on the back of
one of the Lamp Switch cards. The back of all the Lamp Switch cards are identical
except, it should be noted, that the ZXO wires, the output from the lamp supply
monitoring transformer (LSupp) and the Solar Cell input must be connected to the
first Lamp Switch card.
Figure 16 – Lamp Switch Card Connections
Security classification
Unrestricted
Version
5
Last Editor
Neil Atkinson
Document Name
ST950 ICM Handbook
Copyright © Siemens Mobility Limited 2018. All Rights Reserved.
PLB
z
32
EARTH
28
GREEN
SUPPLY
24
ZXO-N
(240V)
20
ZXO-LIVE
16
Sen34+ COMMON
14
Sen35+
Sen33+
12
Sen36+
10
8
1R
6
-
4
2R
2
-
PLA
z
32
3A
30
-
28
-
26
-
24
4R
22
-
20
-
18
-
16
-
14
-
12
6R
10
-
8
-
6
-
4
-
2
8G
Sopers Lane, Poole, Dorset, BH17 7ER
b
d
NEUTRAL
30
R/A
26
SUPPLY
ZXO-N
22
(110V)
LSupp-
16
LSupp+
14
12
SOLAR
10
1G
8
-
6
1A
4
2A
2
b
d
3R
32
2G
30
3G
28
4A
26
5A
24
-
22
4G
20
5R
18
5G
16
6G
14
6A
12
7G
10
7A
8
7R
6
8A
4
8R
2
Page
Status
Date
Document No.
Intelligent Traffic Systems
45 of 125
Issued
18-Dec-2018
667/HE/46950/000