and check that the Checksum displayed is the same value that is printed on
the first page of the IC4 printout (Configuration Check Value)
The RS232 handset command 'CRC' can also be used to check the CRC
value against the IC4 printout.
Finally, before the cabinet leaves the Service Centre:
Tighten the screws on the swing-frame
Place the Junction Plan, the IC4 Printout and the Site Logbook into the pocket
inside the door of the controller
Close and lock the controller door with both key and T-bar locks
Re-package the cabinet with the protective packaging.
7.2

Checking Site Suitability

The controller outer case is installed to suit local conditions, but subject to the
following limitations:
(i) The position of the controller is as shown on the relevant site-to-scale drawing,
(STS)
(ii) No part of the controller is less than 457mm (18 inches) from the kerbside
unless agreed with the customer.
When it is necessary to site the controller less than 2 metres from the outer edge of
the kerb, the access doors and panels should not open over or toward the
carriageway. Where no pedestrian guard rails are fitted, then a clearance of at least
600mm shall be left between the outer case and kerb edge so that guard rails may
be installed at a later date without the need to disturb the controller installation.
(iii) The controller door(s) should be easily accessible and not extend over the
roadway or obstruct the footpath when opened. The door describes an arc of
approx. 710mm radius from the left-hand front corner. Note that the controller door
swings open through 180.
(iv) Any person having control over the junction, whether manual control or
stimulating some other system interface to test the controller's response, MUST
have a good view of the intersection.
(v) When the controller is to be located on unmade ground (e.g. a grass verge) it is
recommended that paving slabs or a concrete standing be provided at ground level
under all access doors and panels. The hard standing shall extend a minimum
distance of 900mm away from the main doors, extending the full width of the case,
Security classification
Version
Last Editor
Document Name
Copyright © Siemens Mobility Limited 2018. All Rights Reserved.
The key lock should not be operated unless the screw locks are tight,
i.e. Unlock the case before undoing the screw lock and only lock the
case after tightening the screw locks.
Unrestricted
5
Neil Atkinson
ST950 ICM Handbook
Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Page
60 of 125
Status
Issued
Date
18-Dec-2018
Document No.
667/HE/46950/000