Samples/Time Between Changes

Write security: 3; Read security: 5
This value is the minimum time between bandwidth changes for this Connec-
tion List profile. The range is 0 to 255 seconds. The default is 60 seconds.

Connection List/Filters

The Express XL/XLT can block packets in and out of a WAN port by use of the
filters. These filters are set up on a per-Connection List profile basis. They are
set up in two steps: 1) define the types of packets that would be of interest in
the Configuration/Security/Filter Defines menu, and 2) set up the filter type
and combination of defines that will cause a packet block.
Typical example of a filter setup:

Filters/WAN-to-LAN (In)

Write security: 2; Read security: 5
The packets which come into the Express XL/XLT can be filtered in three
ways:
Disabled (def) - Turns off packet input filtering. No incoming
packets are blocked.
Block All - All incoming packets from the WAN are blocked
except as defined in the Filters/In Exceptions list.
Forward All - All incoming packets from the WAN are not
blocked except as defined in the Filters/In Exceptions list.
61200.070L1-1
Chapter 3: Terminal Menu Operation and Structure
Express XL/XLT User Manual
79