Introduction
Horizontal separation offers many advantages over traditional fixed-angle separations, including tighter straight-line gel separa-
tions to reduce re-spins and re-mixes. The ComboXL centrifuge spins test tubes from 3ml to 15ml, and even 50ml, at speeds up to
4,000 rpm, with microprocessor speed control. Simply program the digital time and speed and the ComboXL centrifuge will lock the
lid and spin the load. G-forces up to 2,683g's will produce serum in minutes, or reduce the speed for urine sediment and other sepa-
rations. The zero-rpm interlocking metal lid will stay locked until the rotor has come to a stop, to ensure safety. The all-metal rotor
buckets are built for strength and durability, and the wide-mouth metal bowl allows for easy cleanup. The whisper-quiet heavy-duty
brushless DC motor can handle high volume use and high-speed full loads for years to come.
ComboXL Centrifuge
100 Lauman Lane, Suite A, Hicksville, NY 11801
F. 770.270.2389
F. 770.270.2389
Tel: (877) 877-7274 | Fax: (516) 801-2046
865 Marathon Parkway Lawrenceville GA 30046
Email: Info@nyscopes.com
www.microscopeinternational.com
Instruction Manual
865 Marathon Parkway Lawrenceville GA 30046
MKT-7.5.3.-L-215 | Rev 0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ComboXL Centrifuge and is the answer not in the manual?

Questions and answers

Summary of Contents for LW Scientific ComboXL Centrifuge

  • Page 1 Horizontal separation offers many advantages over traditional fixed-angle separations, including tighter straight-line gel separa- tions to reduce re-spins and re-mixes. The ComboXL centrifuge spins test tubes from 3ml to 15ml, and even 50ml, at speeds up to 4,000 rpm, with microprocessor speed control. Simply program the digital time and speed and the ComboXL centrifuge will lock the lid and spin the load.
  • Page 2 Before Operating LW Scientific packs each ComboXL centrifuge with utmost care. All units undergo a QC check prior to shipping from LW Scientific headquarters in Lawrenceville, GA to ensure proper operation. Examine the outer and inner packaging for any visible damage, and retain the packing material.
  • Page 3 (for Fecal Hints, please contact LW Scientific). Proper balancing will improve sample separation and will extend the life of the centrifuge. Spinning out-of-balance loads may break tubes or may cause the unit to shut down due to imbalance detection.
  • Page 4 Contact LW Scientific for return instructions, so the rotor can be evaluated by an LW Scientific technician for repair or replacement. It is also recommended that after 2 years of service rotors, buckets, and tube shields be returned to LW Scientific for inspection.

Table of Contents