Danfoss EKC 414A Manual page 10

Controller for controlling one evaporator
Hide thumbs Also See for EKC 414A:
Table of Contents

Advertisement

Service
A number of controller values can be printed for use in a service situation
Read the temperature at the S5 (S
Read status of input DI
Read the duration of the ongoing defrost or the duration of the last completed
defrost.
Read the temperature at the S3 (S
Read status at the day-/night operation (night operation: on/off )
Read status at the ON input
Read status at the DO output
Read the temperature at the S4 (S
Read the temperature according to which the thermostat function regulate
Read the ongoing cutin time for the thermostat or the duration of the last completed
cutin
Read the temperature at the S2 sensor
Read superheat
Read the control's actual superheat reference
Read the valve's actual opening degree
Read the evaporating pressure in bar
Read the evaporating pressure in degrees
Factory setting
If you need to zeroset the controller and reset the factory-set values, do it like this:
switch off the supply voltage – keep both buttons pushed in at the same time as you
reconnect the supply voltage.
Fault message
In an error situation the LED's on theEKA 162 will flash and the relay will be activated.
If you push the top button in this situation you can see the alarm report in the display.
There are two kinds of error reports - it can either be an alarm occurring during the
daily operation, or there may be a defect in the installation.
A-alarms will not become visible until the set time delay has expired.
E-alarms, on the other hand, will become visible the moment the error occurs.
(An A alarm will not be visible as long as there is an active E alarm).
High temperature alarm
Low temperature alarm
10
) sensor (calibrated value)
def
) sensor (calibrated value)
in
) sensor (calibrated value)
out
Manual RS8CK502 © Danfoss 05-2005
Service
u09
Sdef temp.°C
u10
DI 1 status
u11
Defrost time (Depicted in the "Defrost
control" illustration)
u12
Sin air temp
u13
Night Cond (Depicted in the "Thermo-
stat control" illustration)
u14
Inject ON
u15
DO 1 status
u16
Sout Air Temp.
u17
Ther. air
u18
Ther. runtime (Depicted in the "Ther-
mostat control" illustration)
u20
S2 temp.
u21
SH (Depicted in the "Injection control"
illustration)
u22
SH ref. (Depicted in the "Injection
control" illustration)
u23
AKV OD%
u25
Evap. pres. P0
u26
Evap. temp. T0
Compressor relay
Here you can read the relay status.
Defrost relay
Here you can read the relay status.
Fan relay
Here you can read the relay status.
Alarm relay
Here you can read the relay status.
Light relay
Here you can read the relay status.
Manual control
Set in pos. OFF whereupon the
required output can be force-control-
led. Remember to reset the function
to OFF.
AKV OD% set
Alarm set
Comp. set
Defrost set
Fan set
Light set
DO1 set
Alarm text
The importance of the individual
alarms can be defined with a setting
(0, 1, 2 or 3) in the menu Alarm desti-
nations. See AKM literature.
A1
High Temp. air
A2
Low temp. air
EKC 414A