ICSTT-RM311R-EN-P (PD-TC200)
Trusted
Trusted I/O Companion Slot Cables
Product Overview
This document provides detailed information for the types of Trusted® input/output (I/O) Cables
available within the Companion Slot group. These types of cable provide connection facilities
between the Trusted analogue and digital I/O modules, and Trusted Field Termination Assemblies
(FTAs) or Trusted Versatile Field Termination Assemblies (VFTAs) as required. Cables are also
available with a 'flying lead' at one end to allow connection to conditioned terminals.
The types of Trusted I/O Companion Slot Cables currently available are listed in Table 1 on page 4.
The cables are manufactured to user's requirements; therefore length and type of cable insulation
must be specified. Length must be specified to the nearest 0.5 m in the format xmx, e.g. 2m0 for a
cable length of 2.0 m. This detail must be added to the end of the part number. Note that some
cable lengths are preferred options and may be easier to obtain; please refer to Rockwell
Automation for details. The type of cable insulation forms part of the cable part number and is
denoted by 02 for Low Smoke Zero Halogen (LSZH) or 03 for UL Certified cable material. 02 is also
flame retardant to IEC 60332-3 Cat A. When ordering cables, it is recommended that the user
supplies the details as shown in Table 1.
The maximum recommended I/O cable length is 15 m. Cables longer than this may be specified if
necessary but may suffer from voltage drop, offset, crosstalk and noise and will present materials
handling problems.
Internal cables are designed for cables where they are terminated in adjacent enclosures. If the
cable needs to leave the enclosure environment, the external cable has more protection. Note that
the 'external' cables are not armoured and are not suitable for truly external use and must still be
treated with care. These cables will need protection when drawn through a cable route, and should
also not be pulled by the connector(s). They should enter cabinets through transit/compression
blocks and cannot be glanded.
The Companion Slot cables described in this document allow hot-swap modules to be sited in
adjacent slots using a double width chassis socket. For SmartSlot cables, allowing a remote slot to
be assigned as necessary for a hot-swap, refer to Trusted I/O SmartSlot Cables, publication
ICSTT-
RM313
(PD-TC500).
Rockwell Automation Publication ICSTT-RM311R-EN-P
Issue 21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Trusted TC-201-02 m Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rockwell Automation Trusted TC-201-02 m Series

  • Page 1 The Companion Slot cables described in this document allow hot-swap modules to be sited in adjacent slots using a double width chassis socket. For SmartSlot cables, allowing a remote slot to be assigned as necessary for a hot-swap, refer to Trusted I/O SmartSlot Cables, publication ICSTT- RM313 (PD-TC500). Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 2 This document describes cables for Triple Modular Redundant (TMR) modules (typically 40 channel). For dual modules (typically 60 channel), refer to Trusted Dual I/O SmartSlot Cables, publication ICSTT-RM314 (PD-TC600) and Trusted Dual I/O Companion Slot Cables, publication ICSTT-RM315 (PD-TC700). Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 3 PREFACE PREFACE In no event will Rockwell Automation be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples given in this manual are included solely for illustrative purposes. Because of the many variables and requirements related to any particular installation, Rockwell Automation does not assume responsibility or reliability for actual use based on the examples and diagrams.
  • Page 4 "Sign Up" link at the top right of the web page. DOCUMENTATION FEEDBACK Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en- e.pdf. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 5 IMPORTANT Identifies information that is critical for successful application and understanding of the product. NOTE Provides key information about the product or service. Tips give helpful information about using or setting up the equipment. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 6 CAUTION: The module PCBs contains static sensitive components. Static handling precautions must be observed. DO NOT touch exposed connector pins or attempt to dismantle a module. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 7 TC-223-02-xMx. Not published. Removed information about cables that are no longer offered. Feb 19 Added trademarks statement. Updated to display Rockwell Automation publication numbers. May 19 Added information about -03 suffix (UL) cables. Jul 19 Updated for the T8425 release.
  • Page 8 PREFACE Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 9: Table Of Contents

    I/O Companion Slot Cable Type TC-215 ..............31 I/O Companion Slot Cable Type TC-216 ..............33 I/O Companion Slot Cable Type TC-218 ..............35 I/O Companion Slot Cable Type TC-221 ..............37 I/O Companion Slot Cable Type TC-223 ..............39 Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 10 Table of Contents Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 11: Companion Slot Cable Types And Selection Guides

    I/O Companion Slot, Internal, 40 Channel Output to VFTA (UL) TC-210-02-xmx I/O Companion Slot, External, 40 Channel Output to VFTA TC-210-03-xmx I/O Companion Slot, External, 40 Channel Output to VFTA (UL) TC-211-02-xmx I/O Companion Slot, Internal, 40 Channel Input to VFTA Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 12 Power) (UL) TC-223-02-xmx I/O Companion Slot Internal 40 Channel AC Input from T8824 FTA TC-223-03-xmx I/O Companion Slot Internal 40 Channel AC Input from T8824 FTA (UL) Table 1 Trusted I/O Companion Slot Cables Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 13 INPUT TC-601- INTERNAL COMPANION SLOT INPUT TC-701- Table 3 Dual 60 Channel Standard Cable Selection Guide The various types of I/O Companion Slot Cables, i.e. TC-201, TC-202 etc. are described in the following sections. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 14 1. Companion Slot Cable Types and Selection Guides Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 15: I/O Companion Slot Cable Type Tc-201

    At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 16 2. I/O Companion Slot Cable Type TC-201 Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 17: I/O Companion Slot Cable Type Tc-202

    At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 18 3. I/O Companion Slot Cable Type TC-202 Trusted I/O Companion Slot Cables NOTE The TC-202 cable does not support the T8425 module because the T8425 module requires the attenuation found on the T8825 FTA for proper operation. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 19: I/O Companion Slot Cable Type Tc-203

    At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 20 4. I/O Companion Slot Cable Type TC-203 Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 21: I/O Companion Slot Cable Type Tc-204

    At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 22 5. I/O Companion Slot Cable Type TC-204 Trusted I/O Companion Slot Cables NOTE The TC-204 cable does not support the T8425 module because the T8425 module requires the attenuation found on the T8825 FTA for proper operation. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 23: I/O Companion Slot Cable Type Tc-205

    The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection between this field supply and the T8290 Output Power Distribution Unit (TB1 pins 1 and 2). Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 24 At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 25: I/O Companion Slot Cable Type Tc-206

    0 Volts. The flying lead multi-core contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 26 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 27: I/O Companion Slot Cable Type Tc-207

    2.5 mm wires contained within Rilgain sleeving. The 0 V connection at the chassis end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 28 At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 29: I/O Companion Slot Cable Type Tc-208

    V FIELD RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The 0 V connections at the flying leads end allows a module reference so that it can measure its output voltage, these must be connected to the field 0 Volts. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 30 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 31: I/O Companion Slot Cable Type Tc-209

    T8297 is recommended. The 0 V connection at the VFTA end allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 32 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 33: I/O Companion Slot Cable Type Tc-210

    0 Volts. The VFTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 34 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 35: I/O Companion Slot Cable Type Tc-211

    At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 36 12. I/O Companion Slot Cable Type TC-211 Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 37: I/O Companion Slot Cable Type Tc-212

    At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 38 13. I/O Companion Slot Cable Type TC-212 Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 39: I/O Companion Slot Cable Type Tc-215

    0 Volts. The FTA contains isolated power group field 0 Volts which connect to field 0 V supply. Commoning of the reference is obtained by a connection to this field supply. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 40 At both the chassis and remote end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 41: I/O Companion Slot Cable Type Tc-216

    RTNGRP1 to V FIELD RTNGRP5 for group reference terminations. The multi-core cable is stripped back 1.5 m at both ends, then shrouded in nylon Rilgain sheathing. The ends of the sheathing are heated or fitted with over sleeving to help prevent fraying. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 42 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 43: I/O Companion Slot Cable Type Tc-218

    The ends of the sheathing are heated or fitted with over sleeving to help prevent fraying. The 0 V connections at the flying lead ends allows a module reference so that it can measure its output voltage, this must be connected to the field 0 Volts. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 44 At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 45: I/O Companion Slot Cable Type Tc-221

    The ends of the sheathing are heated or fitted with over sleeving to help prevent fraying. At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...
  • Page 46 17. I/O Companion Slot Cable Type TC-221 Trusted I/O Companion Slot Cables Page intentionally left blank Issue 21 Rockwell Automation Publication ICSTT-RM311R-EN-P...
  • Page 47: I/O Companion Slot Cable Type Tc-223

    At the chassis end, a sheathed braid allows the connector hood to be wired to safety earth. At the remote end, the multi-core screen drain is wired to a green wire to allow connection to screen earth. Rockwell Automation Publication ICSTT-RM311R-EN-P Issue 21...