Pentair Pool Products CC50 Owner's Manual page 115

Clean & clear cartridge filter
Hide thumbs Also See for Pool Products CC50:
Table of Contents

Advertisement

Available languages

Available languages

Problem
Possible Cause
Control panel LCD screen
Loose drive wiring connection.
displays sporadically or
flickers on/off.
Mechanical troubles and
The pump motor is running but with loud noise.
noise.
Foreign matter (gravel, metal, etc.) in
pump impeller.
Cavitation.
Speaking noise, especially evident at pump start-
up or slow down.
Pump does not respond
Improper automation setup.
to IntelliTouch,
EasyTouch,
SunTouch, IntelliComm
system commands.
Communication network inoperative.
Corrective Action
Check the connection between the drive and keypad.
See image on page 3. The drive wiring connection
should be tight.
If suction and discharge piping are not adequately
supported, pump assembly will be strained. Do not
mount pump on a wooden platform! Securely mount
on concrete platform for quietest performance.
Disassemble pump, clean impeller, follow pump ser-
vice instructions for reassembly.
Improve suction conditions.
Increase pipe size.
Decrease number of fittings.
Increase discharge pressure.
Inspect motor slinger and motor shaft seal behind
the slinger (NOT the pump's mechanical seal). Apply
lubrication to the motor shaft rubber seals.
1. Be sure that the communication cable is
connected at both ends.
2. Check that the pump local address matches with
the address used in the IntelliTouch control system.
3. Check that the pump has been assigned a circuit
name on the IntelliTouch control system.
4. Ensure that the pump display says
"DISPLAY NOT ACTIVE".
A defective device on the network can inhibit the
proper operation of other network device. Devices
should be disconnected sequentially until the
network starts working.