Clean & Clear
SECTION I.
FILTER INSTALLATION ............................................................................................... 1
SECTION II.
FILTER OPERATION ..................................................................................................... 2
SECTION III.
TROUBLESHOOTING................................................................................................... 6
SECTION IV.
TECHNICAL DATA ....................................................................................................... 7
A. Filter Pressure Loss Chart .......................................................................................... 7
C. Replacement Parts ..................................................................................................... 7
B. Flow Rate Table ......................................................................................................... 7
Before installing this product, read and follow all warning notices and instructions accompanying this
filter. Failure to follow safety warnings and instructions can result in severe injury, death, or property
damage. Call (800) 831-7133 for additional free copies of these instructions.
Attention Installer.
This manual contains important information about the installation, operation and safe
use of this product. This information should be given to the owner/operator of this
equipment.
SECTION I.

FILTER INSTALLATION

A. GENERAL INFORMATION
1. The filter should be mounted on a level concrete slab. Position the filter so that the instructions,
warnings and pressure gauge are visible to the operator. Also, position the filter so that the piping
connections, control valve and drain port are convenient and accessible
for servicing and winterizing.
2. Install electrical controls (e.g., on/off switches, timers control systems,
etc.) at least five (5) feet from the filter. This will allow you enough
room to stand clear of the filter during system start up.
3. Provide sufficient clearance around the filter to permit visual verification
that the clamp is properly installed, see Figure 1.
4. Provide sufficient space above the filter to remove the filter lid for
cleaning and servicing. This distance will vary with the model of filter
you are using. See Table 1, for the required vertical clearance.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit www.pentairpool.com or www.staritepool.com
Rev. D 6-26-09
Cartridge Filter Owners Manual
®
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS

Table of Contents

Important Notice
WARNING
1
Figure 1.
P/N 178556

Advertisement

loading

Summary of Contents for Pentair CC50

  • Page 1: Table Of Contents

    This distance will vary with the model of filter you are using. See Table 1, for the required vertical clearance. Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 •...
  • Page 2: Filter Operation

    O-ring only, there is no need for thread Vertical sealing compounds. Position the filter to safely direct Model Size Clearance Req. water drainage. Rotate the valve to safely direct CC50 160314 50 sq. ft. 30 in. purged air or water. Water discharged from an CC75 160315 75 sq.
  • Page 3 A. GENERAL INFORMATION 1. This filter operates under pressure. When the lock ring is installed properly and operated without air in the water system, this filter will operate in a safe manner. 2. The maximum working pressure of this filter is 50 psi. Never subject this filter to pressure in excess of this amount - even when conducting hydrostatic pressure tests.
  • Page 4 WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE.
  • Page 5 2. Open the filter High Flow™ manual air relief valve, (and the waste drain valve, or cap, if your system has one). NOTE Special care must be taken when cleaning cartridge element used in a swimming pool or spa using Baquacil as a sanitizer.
  • Page 6: Troubleshooting

    F. CLEANING THE HIGH FLOW™ MANUAL AIR RELIEF VALVE 1. Turn the pump off and shut off any automatic controls to ensure that the system is not inadvertently started during servicing. 2. OPEN THE HIGH FLOW™ MANUAL AIR RELIEF VALVE UNTIL IT SNAPS INTO THE FULL OPEN POSITION, THEN WAIT UNTIL ALL PRESSURE IS RELIEVED.
  • Page 7: Technical Data

    SECTION IV. TECHNICAL DATA A. Filter Pressure Loss Chart B. Flow Rate Table l a i l a i PRESSURE LOSS vs FLOW t r a d i r t r a d i r . t f (1) One GPM per sq. ft. shown, recommended flow rate for residential is .5 GPM per sq. ft. (2) Commercial flow rate is a maximum of .375 GPM per sq.
  • Page 8 Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.