HF Option:
G) Place the Washer (Item
11) and then the Long
Spacer (Item 10) onto the
Screw (Item 8). Place a
Short Spacer (Item 9)
over the Long Spacer and
Screw. Insert the Long
Spacer and Screw
through the HF Module
(Item 14). Place a Short
Spacer (Item 9) over the
Long Spacer and Screw
then secure the assembled
parts to the Mounting
Plate, as shown.
H) Affix the FCC Label (Item
13) to the Mounting
Plate. Route the Antenna
Cable behind the
Mounting Plate and then
connect the cables
according to the table
below:
Cable
Antenna Cable
Power Cable (Item 4)
Comm Cable (Item 5)
I/O
Mounting
Plate
Main Logic
CCA
J12
J7
Power
Supply CCA
Antenna
Cable
From
Antenna
J7 – Power Supply CCA
J12 – Main Logic CCA
HF Module
7
Long
Spacer
J2
J1
J3
Mounting
Plate
Antenna
I/O
Port
To
Antenna Port – HF Module
J1 - Regulator CCA
J2 – Regulator CCA
J3 – Regulator CCA
Short
Spacer
HF
Module
Short
Spacer
Screw
Washer
Regulator
CCA
FCC Label
HF
Module