Samsung Electronics DVM Series Technical Manual page 144

Table of Contents

Advertisement

Ι Λ
. Outdoor unit
3. Functional parts and safety devices
Item
Code
-
Compressor
-
Compressor safety OLP
CCH
Motor
Safety thermostat
Safety
HPS
devices
LPS
HPSO
LPSO
DTS
CMS
Thermistor (condenser center)
COS
Thermistor (condenser outlet)
Temperature
OATS
Thermistor (outdoor temperature)
sensor
SUC.S
OIL.S
FDTS
Thermistor (fixed discharge)
PWM
(for compressor operation)
HGBV
(for bypass of high temperature gas)
LBV
Solenoid valve (liquid injection)
Functional
VBV
Solenoid valve (for exhaust air)
parts
BV1
Solenoid valve (for capacity control)
BV2
Solenoid valve (for capacity control)
4-W/V
C/V
EEV
Electronic expansion valve (for heating)
Name
Motor output
open temp.
trip current
Crank case heater
model
Fan motor
output
on
off
High pressure switch
Low pressure switch
High pressure sensor
Low pressure sensor
Thermistor (discharge)
Suction sensor
Oil sensor
Solenoid valve
Solenoid valve
4-way valve
Coil & Body : Saginomiya, CHV-0401
Check valve
Ι Λ
RVMH050CBM0
ZRD49KC-PFV
3.7kW
248°F
37A
90W
-
128W + 128W
275°F
194°F
OFF : 425 Psig
ON : 315 Psig
-
PS8030A (NH4-H) (0~425 Psig)
PS8030A (NH4-L) (0~??? Psig)
Model : 0166-01, Rt=302°F, 77°F=86Ω
-
103AT (77°F=10kΩ)
103AT (77°F=10kΩ)
103AT (77°F=10kΩ)
103AT (77°F=10kΩ)
204CTB (77°F=200kΩ)
Coil : Copeland (Part # 023-0028-03)
Body : EPV-1530D
Coil : Siginomiya
Body : NEV-603D
Coil : Siginomiya
Body : NEV-202D
-
-
Coil & Body : CHV-0712 (Saginomiya)
Fujikoki (425 Psig)
EDM-60YH (Fujikoki)
6
RVMH100FAM0
ZRDU13MC-TF5
5.5kW + 4.3kW
311°F
70A
90W
OSME4508SRC
450W
302°F
212°F
EDM-AOYH (Fujikoki)

Advertisement