Xylem FloJet 3426 Series Manual

Xylem FloJet 3426 Series Manual

Automatic water system pump

Advertisement

Quick Links

MODEL*
VOLTS
03526144
12V dc
R3626344
24V dc
R3426144
12V dc
R3426344
24V dc
R3426148
12V dc
R3426348
24V dc
*CE fully suppressed models are identified by a prefix "R" and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.
OPERATION
With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
Pump
Series
3X26XXX
AMP DRAW
@10 psi (0.7 bar)
GPM (LPM)
4.4
2.2
4.4
2.2
3.5
1.7
AUTOMATIC WATER SYSTEM PUMP
Height
Length
inches (mm)
inches (mm)
4.75 (121)
9.00 (229)
FLOW
PRESSURE SWITCH
Max psi (bar)
2.9 (11)
50 (3.4)
2.9 (11)
40 (2.8)
2.9 (11)
25 (1.7)
2.9 (11)
25 (1.7)
2.0 (8)
25 (1.7)
2.0 (8)
25 (1.7)
"TRIPLEX DIAPHRAGM"
3426 / 3526 / 3626 SERIES
Width
Weight
inches (mm)
6.00 (152)
3.50 (1.59)
BYPASS
Yes
Yes
Yes
Yes
Yes
Yes
Lb (Kg)

Advertisement

loading

Summary of Contents for Xylem FloJet 3426 Series

  • Page 1 “TRIPLEX DIAPHRAGM” 3426 / 3526 / 3626 SERIES AUTOMATIC WATER SYSTEM PUMP Pump Height Length Width Weight Series inches (mm) inches (mm) inches (mm) Lb (Kg) 3X26XXX 4.75 (121) 9.00 (229) 6.00 (152) 3.50 (1.59) MODEL* VOLTS AMP DRAW FLOW PRESSURE SWITCH BYPASS @10 psi (0.7 bar)
  • Page 2 trouble shooting guide. CAUTION - Pump surface will get hot to the touch if operated for extended periods of time under pressurized conditions. Battery Black ( Switch INSTALLATION WIRING STEP 1 Remove shipping plugs from pump ports. Some water from factory testing may spill out. STEP 2 Connect fittings supplied with the pump to the RV’s plumbing.
  • Page 3: Troubleshooting

    STEP 6 Install a Flojet strainer in an accessible location (for inspection and cleaning) between the tank and pump inlet. This strainer or equivalent is required for pump warranty to be valid. STEP 1 Use 14 gauge stranded wire to 20’, 12 gauge to 50’, from power source.
  • Page 4 • R e s t r i c t e d p u m p d e l i v e r y . C h e c k d i s c h a r g e l i n e s , f i t t i n g s a n d v a l v e s f o r c l o g g i n g o r u n d e r s i z i n g E X P L O D E D V I E W AUTOMATIC WATER SYSTEM PUMP SERVICE PARTS...
  • Page 5: Warranty

    Allowing water to freeze in the system may result in damage to Portable water systems require periodic maintenance to the pump and plumbing system. deliver a consistent flow of fresh water. Depending on use and the environment the system is subject to, Non-Toxic antifreeze for potable water may be used with Flojet sanitizing is recommended prior to storing and before pumps.
  • Page 6: System Care And Maintenance

    Tel: +39 039 685 2323 Fax: 949.608.3887 Fax: +44 (0) 1992 467132 Fax: 045.475.8908 Fax: +49-40-53 53 73 -11 Fax: +39 039 666 307 Jabsco is a trademark of Xylem Inc. or one of its subsidiaries. © 2014 Xylem, Inc. 81000-384 Rev. G 05/2014...

This manual is also suitable for:

Flojet 3526 seriesFlojet 3626 seriesFlojet 03526144Flojet r3626344Flojet r3426144Flojet r3426148 ... Show all